Authentication bypass in the password recovery feature of the local web interface across multiple VIGI camera models allows an attacker on the LAN to reset the admin password without verification by manipulating client-side state. Attackers can gain full administrative access to the device, compromising configuration and network security.
Severity ?
{
"affected": [],
"aliases": [
"CVE-2026-0629"
],
"database_specific": {
"cwe_ids": [
"CWE-287"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2026-01-16T18:16:09Z",
"severity": "HIGH"
},
"details": "Authentication bypass in the password recovery feature of the local web interface across multiple VIGI camera models allows an attacker on the LAN to reset the admin password without verification by manipulating client-side state. Attackers can gain full administrative access to the device, compromising configuration and network security.",
"id": "GHSA-2262-37j2-53g4",
"modified": "2026-01-16T18:31:33Z",
"published": "2026-01-16T18:31:33Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2026-0629"
},
{
"type": "WEB",
"url": "https://www.tp-link.com/us/support/faq/4899"
},
{
"type": "WEB",
"url": "https://www.vigi.com/en/support/download"
},
{
"type": "WEB",
"url": "https://www.vigi.com/in/support/download"
},
{
"type": "WEB",
"url": "https://www.vigi.com/us/support/download"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
CVE-2026-0629 (GCVE-0-2026-0629)
Vulnerability from cvelistv5 – Published: 2026-01-16 17:24 – Updated: 2026-01-17 04:55
VLAI?
EPSS
Title
Authentication Bypass in Password Recovery Feature via Local Web App on Multiple VIGI Cameras
Summary
Authentication bypass in the password recovery feature of the local web interface across multiple VIGI camera models allows an attacker on the LAN to reset the admin password without verification by manipulating client-side state. Attackers can gain full administrative access to the device, compromising configuration and network security.
Severity ?
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TP-Link Systems Inc. | VIGI InSight Sx45 Series (S245/S345/S445) |
Affected:
0 , < 3.1.0_Build_250820_Rel.57668n
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Credits
Mohmad Hafiz from Swarmnetics
Arko Dhar from Redinent Innovations Pvt Ltd.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-0629",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-16T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-17T04:55:23.748Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight Sx45 Series (S245/S345/S445)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.1.0_Build_250820_Rel.57668n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx45 Series (C345/C445)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.1.0_Build_250820_Rel.57668n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight Sx55 Series (S355/S455)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.1.0_Build_250820_Rel.58873n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx55 Series (C355/C455)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.1.0_Build_250820_Rel.58873n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight Sx85 Series (S285/S385)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.0.2_Build_250630_Rel.71279n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx85 Series (C385/C485)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.0.2_Build_250630_Rel.71279n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight S655I",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.1_Build_250625_Rel.64224n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight Sx45ZI Series (S245ZI/S345ZI/S445ZI)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0_Build_250820_Rel.60930n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight Sx85PI Series (S385PI/S485PI)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0_Build_250827_Rel.66817n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C340S",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.1.0_Build_250625_Rel.65381n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C540S / EasyCam C540S",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.1.0_Build_250625_Rel.66601n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C540V",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250702_Rel.54300n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C250",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250702_Rel.54301n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx50 Series (C350/C450)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250702_Rel.54294n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx20I 1.0 Series (C220I 1.0/C320I 1.0/C420I 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_251014_Rel.58331n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx20I 1.20 Series (C220I 1.20/C320I 1.20/C420I 1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.44071n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx30I 1.0 Series (C230I 1.0/C330I 1.0/C430I 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.45506n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx30I 1.20 Series (C230I 1.20/C330I 1.20/C430I 1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.44555n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx40I 1.0 Series (C240I 1.0/C340I 1.0/C440I 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.46003n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx40I 1.20 Series (C240I 1.20/C340I 1.20/C440I 1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.45041n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx30 1.0 Series (C230 1.0/C330 1.0/C430 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.46796n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx30 1.20 Series (C230 1.20/C330 1.20/C430 1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.46796n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C230I Mini",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.47570n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C240 1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.48425n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C340 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.49304n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C440 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.49778n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C540 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.50397n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C540-4G",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.0_Build_250826_Rel.56808n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C340-W 2.x Series (C340-W 2.0/C340-W 2.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.1_Build_250717_Rel.66528n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C440-W 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.1_Build_250717_Rel.66632n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI C540-W 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.1_Build_250717_Rel.67730n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight S345-4G",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250725_Rel.36867n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI InSight Sx25 Series (S225/S325/S425)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0_Build_250630_Rel.39597n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web app"
],
"product": "VIGI Cx20 Series (C320/C420)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0_Build_250701_Rel.39597n",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mohmad Hafiz from Swarmnetics"
},
{
"lang": "en",
"type": "finder",
"value": "Arko Dhar from Redinent Innovations Pvt Ltd."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Authentication bypass in the password recovery feature of the local web interface across multiple VIGI camera models allows an attacker on the LAN to reset the admin password without verification by manipulating client-side state. Attackers can gain full administrative access to the device, compromising configuration and network security.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Authentication bypass in the password recovery feature of the local web interface across multiple VIGI camera models allows an attacker on the LAN to reset the admin password without verification by manipulating client-side state. Attackers can gain full administrative access to the device, compromising configuration and network security."
}
],
"impacts": [
{
"capecId": "CAPEC-207",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-207 Removing Important Client Functionality"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-17T00:51:48.830Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://www.vigi.com/us/support/download/"
},
{
"tags": [
"patch"
],
"url": "https://www.vigi.com/en/support/download/"
},
{
"tags": [
"patch"
],
"url": "https://www.vigi.com/in/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/4899/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication Bypass in Password Recovery Feature via Local Web App on Multiple VIGI Cameras",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-0629",
"datePublished": "2026-01-16T17:24:39.370Z",
"dateReserved": "2026-01-06T00:07:04.905Z",
"dateUpdated": "2026-01-17T04:55:23.748Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…