GHSA-3484-2RVH-885X
Vulnerability from github – Published: 2024-05-03 03:30 – Updated: 2024-05-03 03:30
VLAI?
Details
NETGEAR ProSAFE Network Management System clearAlertByIds SQL Injection Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the clearAlertByIds function. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. Was ZDI-CAN-19724.
Severity ?
8.8 (High)
{
"affected": [],
"aliases": [
"CVE-2023-38100"
],
"database_specific": {
"cwe_ids": [
"CWE-89"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-05-03T02:15:52Z",
"severity": "HIGH"
},
"details": "NETGEAR ProSAFE Network Management System clearAlertByIds SQL Injection Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the clearAlertByIds function. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. Was ZDI-CAN-19724.",
"id": "GHSA-3484-2rvh-885x",
"modified": "2024-05-03T03:30:55Z",
"published": "2024-05-03T03:30:55Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-38100"
},
{
"type": "WEB",
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
},
{
"type": "WEB",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-916"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.