ghsa-459j-fx99-4969
Vulnerability from github
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0::::::: cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1::::::: cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2::::::: cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3::::::: cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:::::::
{ "affected": [], "aliases": [ "CVE-2022-29922" ], "database_specific": { "cwe_ids": [ "CWE-20" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-09-14T18:15:00Z", "severity": "HIGH" }, "details": "Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*", "id": "GHSA-459j-fx99-4969", "modified": "2022-09-18T00:00:31Z", "published": "2022-09-15T00:00:16Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-29922" }, { "type": "WEB", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.