ghsa-53pq-r3c7-x97x
Vulnerability from github
Published
2022-05-24 17:44
Modified
2023-10-10 18:31
Severity
Details

In SIMATIC MV400 family versions prior to v7.0.6, the ISN generator is initialized with a constant value and has constant increments. An attacker could predict and hijack TCP sessions.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2020-27632"
  ],
  "database_specific": {
    "cwe_ids": [],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2021-03-10T18:15:00Z",
    "severity": "HIGH"
  },
  "details": "In SIMATIC MV400 family versions prior to v7.0.6, the ISN generator is initialized with a constant value and has constant increments. An attacker could predict and hijack TCP sessions.",
  "id": "GHSA-53pq-r3c7-x97x",
  "modified": "2023-10-10T18:31:31Z",
  "published": "2022-05-24T17:44:03Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-27632"
    },
    {
      "type": "WEB",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599268.pdf"
    },
    {
      "type": "WEB",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-042-01"
    },
    {
      "type": "WEB",
      "url": "https://www.forescout.com/resources/numberjack-weak-isn-generation-in-embedded-tcpip-stacks"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
      "type": "CVSS_V3"
    }
  ]
}