Action not permitted
Modal body text goes here.
ghsa-5x5p-62r5-2xx8
Vulnerability from github
Published
2024-05-14 18:30
Modified
2024-05-14 18:30
Severity ?
Details
Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
{ "affected": [], "aliases": [ "CVE-2024-1486" ], "database_specific": { "cwe_ids": [ "CWE-732" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-05-14T16:15:57Z", "severity": "HIGH" }, "details": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices", "id": "GHSA-5x5p-62r5-2xx8", "modified": "2024-05-14T18:30:58Z", "published": "2024-05-14T18:30:58Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-1486" }, { "type": "WEB", "url": "https://securityupdate.gehealthcare.com" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
cve-2024-1486
Vulnerability from cvelistv5
Published
2024-05-14 15:10
Modified
2024-08-16 18:15
Severity ?
EPSS score ?
Summary
Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T18:40:21.121Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://securityupdate.gehealthcare.com/" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "venue_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "venue_go_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "venue_fit_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "logiq_e_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.2", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "logiq_he_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_e_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" }, { "lessThanOrEqual": "113.2", "status": "affected", "version": "E9 113.2", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_s_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_t_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_iq_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "invenia_abus_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "1.2.3" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "invenia_abus_2.0_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "2.2.9", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-1486", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-12T14:08:59.014421Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-16T18:15:02.675Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.2", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" }, { "lessThanOrEqual": "113.2", "status": "affected", "version": "E9 113.2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Invenia ABUS", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "1.2.3" } ] }, { "defaultStatus": "unaffected", "product": "Invenia ABUS 2.0", "vendor": "GE HealthCare", "versions": [ { "lessThan": "2.2.9", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices" } ], "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices" } ], "impacts": [ { "capecId": "CAPEC-1", "descriptions": [ { "lang": "en", "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-14T15:10:22.262Z", "orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC" }, "references": [ { "url": "https://securityupdate.gehealthcare.com/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "assignerShortName": "GEHC", "cveId": "CVE-2024-1486", "datePublished": "2024-05-14T15:10:22.262Z", "dateReserved": "2024-02-13T22:34:57.386Z", "dateUpdated": "2024-08-16T18:15:02.675Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.