GHSA-9V8P-C94C-Q287
Vulnerability from github – Published: 2022-05-24 17:08 – Updated: 2022-12-13 18:30A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (all versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (all versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
{
"affected": [],
"aliases": [
"CVE-2019-13924"
],
"database_specific": {
"cwe_ids": [
"CWE-1021",
"CWE-693"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-02-11T16:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (all versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (all versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GHSA-9v8p-c94c-q287",
"modified": "2022-12-13T18:30:27Z",
"published": "2022-05-24T17:08:23Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-13924"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
},
{
"type": "WEB",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"type": "CVSS_V3"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.