Multiple W&T Products of the ComServer Series are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into the title of the configuration webpage
Severity ?
8.0 (High)
{
"affected": [],
"aliases": [
"CVE-2022-42786"
],
"database_specific": {
"cwe_ids": [
"CWE-79"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-11-10T12:15:00Z",
"severity": "HIGH"
},
"details": "Multiple W\u0026T Products of the ComServer Series are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into the title of the configuration webpage",
"id": "GHSA-ffmc-cj3h-9wwj",
"modified": "2022-11-10T19:01:11Z",
"published": "2022-11-10T19:01:11Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-42786"
},
{
"type": "WEB",
"url": "https://cert.vde.com/de/advisories/VDE-2022-043"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
CVE-2022-42786 (GCVE-0-2022-42786)
Vulnerability from cvelistv5 – Published: 2022-11-10 11:02 – Updated: 2025-04-29 14:56
VLAI?
EPSS
Title
Wiesemann & Theis: XSS vulnerability in web interface of the Com-Server family
Summary
Multiple W&T Products of the ComServer Series are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into the title of the configuration webpage
Severity ?
5.4 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:04.411Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/de/advisories/VDE-2022-043/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42786",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-29T14:56:37.167104Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-29T14:56:50.373Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Com-Server LC",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.48",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server PoE 3 x Isolated",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.48",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server 20mA",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.48",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server ++",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.48",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AT-Modem-Emulator",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.48",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server UL",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.48",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed 100BaseFX",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed 100BaseLX",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed Office 1 Port",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed Office 4 Port",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed Industry",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed OEM",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed Compact",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed Isolated",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed 19\" 1Port",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed 19\" 4Port",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Com-Server Highspeed PoE",
"vendor": "Wiesemann \u0026 Theis",
"versions": [
{
"lessThan": "1.76",
"status": "affected",
"version": "1.0",
"versionType": "semver"
}
]
}
],
"datePublic": "2022-11-07T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Multiple W\u0026amp;T Products of the ComServer Series are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into the title of the configuration webpage"
}
],
"value": "Multiple W\u0026T Products of the ComServer Series are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into the title of the configuration webpage"
}
],
"impacts": [
{
"capecId": "CAPEC-32",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-32 XSS Through HTTP Query Strings"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-16T08:53:50.333Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/de/advisories/VDE-2022-043/"
}
],
"source": {
"advisory": "VDE-2022-043",
"defect": [
"CERT@VDE#64257"
],
"discovery": "EXTERNAL"
},
"title": "Wiesemann \u0026 Theis: XSS vulnerability in web interface of the Com-Server family",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-42786",
"datePublished": "2022-11-10T11:02:32.615Z",
"dateReserved": "2022-10-11T13:32:19.672Z",
"dateUpdated": "2025-04-29T14:56:50.373Z",
"requesterUserId": "a1e5283b-8f0d-401e-98b2-bc6219c0e8d1",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…