A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. An attacker could use this vulnerability to compromise availability of the network connectivity. At the time of advisory publication no public exploitation of this vulnerability was known.
{ "affected": [], "aliases": [ "CVE-2018-13805" ], "database_specific": { "cwe_ids": [ "CWE-400" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-10-10T17:29:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions \u003e= V2.0 and \u003c V2.1.6), SIMATIC S7-1500 Software Controller (All versions \u003e= V2.0 and \u003c V2.5), SIMATIC S7-1500 incl. F (All versions \u003e= V2.0 and \u003c V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. An attacker could use this vulnerability to compromise availability of the network connectivity. At the time of advisory publication no public exploitation of this vulnerability was known.", "id": "GHSA-mxvx-9h7h-6vxh", "modified": "2022-05-14T01:18:13Z", "published": "2022-05-14T01:18:13Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-13805" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-347726.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.