ghsa-pjx6-jj7c-74m7
Vulnerability from github
Published
2022-05-24 17:22
Modified
2022-08-11 00:00
Details

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.

Show details on source website


{
   affected: [],
   aliases: [
      "CVE-2020-7587",
   ],
   database_specific: {
      cwe_ids: [
         "CWE-400",
      ],
      github_reviewed: false,
      github_reviewed_at: null,
      nvd_published_at: "2020-07-14T14:15:00Z",
      severity: "MODERATE",
   },
   details: "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.",
   id: "GHSA-pjx6-jj7c-74m7",
   modified: "2022-08-11T00:00:20Z",
   published: "2022-05-24T17:22:55Z",
   references: [
      {
         type: "ADVISORY",
         url: "https://nvd.nist.gov/vuln/detail/CVE-2020-7587",
      },
      {
         type: "WEB",
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
      },
   ],
   schema_version: "1.4.0",
   severity: [
      {
         score: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L",
         type: "CVSS_V3",
      },
   ],
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.