A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2018-13813"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-601"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2018-12-13T16:29:00Z",
    "severity": "HIGH"
  },
  "details": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",
  "id": "GHSA-q5p9-4pqr-fw9h",
  "modified": "2022-05-13T01:34:42Z",
  "published": "2022-05-13T01:34:42Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-13813"
    },
    {
      "type": "WEB",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
    },
    {
      "type": "WEB",
      "url": "http://www.securityfocus.com/bid/105922"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
      "type": "CVSS_V3"
    }
  ]
}