ghsa-q833-7p8r-rcqc
Vulnerability from github
Published
2022-05-24 16:45
Modified
2022-05-24 16:45
Details

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Show details on source website


{
  "affected": [],
  "aliases": [
    "CVE-2019-6572"
  ],
  "database_specific": {
    "cwe_ids": [],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2019-05-14T20:29:00Z",
    "severity": "CRITICAL"
  },
  "details": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
  "id": "GHSA-q833-7p8r-rcqc",
  "modified": "2022-05-24T16:45:40Z",
  "published": "2022-05-24T16:45:40Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-6572"
    },
    {
      "type": "WEB",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
    },
    {
      "type": "WEB",
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
    },
    {
      "type": "WEB",
      "url": "http://www.securityfocus.com/bid/108412"
    }
  ],
  "schema_version": "1.4.0",
  "severity": []
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.