Action not permitted
Modal body text goes here.
Modal Title
Modal Body
GHSA-Q9CJ-QF3M-4WRV
Vulnerability from github – Published: 2024-04-19 00:30 – Updated: 2024-04-19 00:30
VLAI?
Details
Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.
Severity ?
7.5 (High)
{
"affected": [],
"aliases": [
"CVE-2024-3742"
],
"database_specific": {
"cwe_ids": [
"CWE-312"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-04-18T23:15:07Z",
"severity": "HIGH"
},
"details": "\nElectrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.\n\n",
"id": "GHSA-q9cj-qf3m-4wrv",
"modified": "2024-04-19T00:30:54Z",
"published": "2024-04-19T00:30:54Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-3742"
},
{
"type": "WEB",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"type": "CVSS_V3"
}
]
}
CVE-2024-3742 (GCVE-0-2024-3742)
Vulnerability from cvelistv5 – Published: 2024-04-18 22:15 – Updated: 2024-08-01 20:20
VLAI?
EPSS
Title
Electrolink FM/DAB/TV Transmitter Cleartext Storage of Sensitive Information
Summary
Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.
Severity ?
CWE
- CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrolink | Compact DAB Transmitter |
Affected:
10W
Affected: 100W Affected: 250W |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
Credits
Gjoko Krstic publicly reported these vulnerabilities on the internet after an unsuccessful attempt to contact Electrolink directly.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:electrolink:medium_dab_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "medium dab transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "2kW, 1kW, 500W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:digital_fm_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "digital fm transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "15W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:vhf_tv_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "vhf tv transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "BI"
},
{
"status": "affected",
"version": "BIII"
},
{
"status": "affected",
"version": "10W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:high_power_dab_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "high power dab transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "5kW"
},
{
"status": "affected",
"version": "4kW"
},
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "2.5kW"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:compact_dab_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact dab transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "10W"
},
{
"status": "affected",
"version": "100W"
},
{
"status": "affected",
"version": "250W"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:modular_fm_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modular fm transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "5kW"
},
{
"status": "affected",
"version": "10kW"
},
{
"status": "affected",
"version": "15kW"
},
{
"status": "affected",
"version": "20kW"
},
{
"status": "affected",
"version": "30kW"
}
]
},
{
"cpes": [
"cpe:2.3:a:electrolink:compact_fm_transmitter:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact fm transmitter",
"vendor": "electrolink",
"versions": [
{
"status": "affected",
"version": "500W"
},
{
"status": "affected",
"version": "1kW"
},
{
"status": "affected",
"version": "2kW"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3742",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T15:38:32.607032Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:32:02.128Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:00.923Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Compact DAB Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "10W"
},
{
"status": "affected",
"version": "100W"
},
{
"status": "affected",
"version": "250W"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Medium DAB Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "500W"
},
{
"status": "affected",
"version": "1kW"
},
{
"status": "affected",
"version": "2kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "High Power DAB Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "2.5kW"
},
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "4kW"
},
{
"status": "affected",
"version": "5kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact FM Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "Compact FM Transmitter"
},
{
"status": "affected",
"version": "500W"
},
{
"status": "affected",
"version": "1kW"
},
{
"status": "affected",
"version": "2kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modular FM Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "3kW"
},
{
"status": "affected",
"version": "5kW"
},
{
"status": "affected",
"version": "10kW"
},
{
"status": "affected",
"version": "15kW"
},
{
"status": "affected",
"version": "20kW"
},
{
"status": "affected",
"version": "30kW"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Digital FM Transmitter",
"vendor": "Electrolink",
"versions": [
{
"lessThanOrEqual": "40kW",
"status": "affected",
"version": "15W",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VHF TV Transmitter",
"vendor": "Electrolink",
"versions": [
{
"status": "affected",
"version": "BI"
},
{
"status": "affected",
"version": "BIII"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UHF TV Transmitter",
"vendor": "Electrolink",
"versions": [
{
"lessThanOrEqual": "5kW",
"status": "affected",
"version": "10W",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gjoko Krstic publicly reported these vulnerabilities on the internet after an unsuccessful attempt to contact Electrolink directly."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system."
}
],
"value": "Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-28T16:52:22.524Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-02"
}
],
"source": {
"advisory": "ICSA-24-107-02",
"discovery": "EXTERNAL"
},
"title": "Electrolink FM/DAB/TV Transmitter Cleartext Storage of Sensitive Information",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Electrolink has not responded to requests to work with CISA to mitigate \nthese vulnerabilities. Users of the affected products are encouraged to \ncontact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://electrolink.com/contacts/\"\u003eElectrolink\u003c/a\u003e for additional information.\n\n\u003cbr\u003e"
}
],
"value": "Electrolink has not responded to requests to work with CISA to mitigate \nthese vulnerabilities. Users of the affected products are encouraged to \ncontact Electrolink https://electrolink.com/contacts/ for additional information."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-3742",
"datePublished": "2024-04-18T22:15:35.521Z",
"dateReserved": "2024-04-12T19:46:39.173Z",
"dateUpdated": "2024-08-01T20:20:00.923Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…