"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:03:44.886Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Central Licensing System",
"vendor": "ABB",
"versions": [
{
"lessThan": "5*",
"status": "affected",
"version": "5.1",
"versionType": "custom"
}
]
},
{
"product": "ABB Ability System 800xA",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "5.1"
},
{
"status": "affected",
"version": "6.0"
},
{
"status": "affected",
"version": "6.1"
}
]
},
{
"product": "Compact HMI",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "5.1"
},
{
"status": "affected",
"version": "6.0"
}
]
},
{
"product": "Control Builder Safe",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "1.0"
},
{
"status": "affected",
"version": "1.1"
},
{
"status": "affected",
"version": "2.0"
}
]
},
{
"product": "Symphony Plus S+ Operations",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "3.2",
"status": "affected",
"version": "3",
"versionType": "custom"
}
]
},
{
"product": "Symphony Plus S+ Engineering ",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "2.2",
"status": "affected",
"version": "1.1",
"versionType": "custom"
}
]
},
{
"product": "Composer Harmony",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "5.1"
},
{
"status": "affected",
"version": "6.0"
},
{
"status": "affected",
"version": "6.1"
}
]
},
{
"product": "Composer Melody ",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "5.3"
},
{
"lessThanOrEqual": "6.3",
"status": "affected",
"version": "6",
"versionType": "custom"
}
]
},
{
"product": "Harmony OPC Server Standalone",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "6.0"
},
{
"status": "affected",
"version": "6.1"
},
{
"status": "affected",
"version": "7.0"
}
]
},
{
"product": "Advant OCS Control Builder A",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "1.3"
},
{
"status": "affected",
"version": "1.4"
}
]
},
{
"product": "Composer CTK",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "6.1"
},
{
"status": "affected",
"version": "6.2"
}
]
},
{
"product": "AdvaBuild",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "3.7 SP1"
},
{
"status": "affected",
"version": "3.7 SP2"
}
]
},
{
"product": "OPC Server for Mod 300 (non-800xA)",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "1.4"
}
]
},
{
"product": "OPC Data Link",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "2.1"
},
{
"status": "affected",
"version": "2.2"
}
]
},
{
"product": "Knowledge Manager",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "8.0"
},
{
"status": "affected",
"version": "9.0"
},
{
"status": "affected",
"version": "9.1"
}
]
},
{
"product": "Manufacturing Operations Management",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "1812"
},
{
"status": "affected",
"version": "1909"
}
]
},
{
"product": "Advant OCS AC 100 OPS Server",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "5.1"
},
{
"status": "affected",
"version": "6.0"
},
{
"status": "affected",
"version": "6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-275",
"description": "CWE-275 Permission Issues",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-09T16:16:51",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ABB Central Licensing System - Weak File Permissions",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"ID": "CVE-2020-8471",
"STATE": "PUBLIC",
"TITLE": "ABB Central Licensing System - Weak File Permissions"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Central Licensing System",
"version": {
"version_data": [
{
"version_affected": "\u003e=",
"version_name": "5",
"version_value": "5.1"
}
]
}
},
{
"product_name": "ABB Ability System 800xA",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1"
},
{
"version_affected": "=",
"version_value": "6.0"
},
{
"version_affected": "=",
"version_value": "6.1"
}
]
}
},
{
"product_name": "Compact HMI",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1"
},
{
"version_affected": "=",
"version_value": "6.0"
}
]
}
},
{
"product_name": "Control Builder Safe",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.0"
},
{
"version_affected": "=",
"version_value": "1.1"
},
{
"version_affected": "=",
"version_value": "2.0"
}
]
}
},
{
"product_name": "Symphony Plus S+ Operations",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3",
"version_value": "3.2"
}
]
}
},
{
"product_name": "Symphony Plus S+ Engineering ",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "1.1",
"version_value": "2.2"
}
]
}
},
{
"product_name": "Composer Harmony",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1"
},
{
"version_affected": "=",
"version_value": "6.0"
},
{
"version_affected": "=",
"version_value": "6.1"
}
]
}
},
{
"product_name": "Composer Melody ",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.3"
},
{
"version_affected": "\u003c=",
"version_name": "6",
"version_value": "6.3"
}
]
}
},
{
"product_name": "Harmony OPC Server Standalone",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "6.0"
},
{
"version_affected": "=",
"version_value": "6.1"
},
{
"version_affected": "=",
"version_value": "7.0"
}
]
}
},
{
"product_name": "Advant OCS Control Builder A",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.3"
},
{
"version_affected": "=",
"version_value": "1.4"
}
]
}
},
{
"product_name": "Composer CTK",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "6.1"
},
{
"version_affected": "=",
"version_value": "6.2"
}
]
}
},
{
"product_name": "AdvaBuild",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "3.7 SP1"
},
{
"version_affected": "=",
"version_value": "3.7 SP2"
}
]
}
},
{
"product_name": "OPC Server for Mod 300 (non-800xA)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.4"
}
]
}
},
{
"product_name": "OPC Data Link",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "2.1"
},
{
"version_affected": "=",
"version_value": "2.2"
}
]
}
},
{
"product_name": "Knowledge Manager",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.0"
},
{
"version_affected": "=",
"version_value": "9.0"
},
{
"version_affected": "=",
"version_value": "9.1"
}
]
}
},
{
"product_name": "Manufacturing Operations Management",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1812"
},
{
"version_affected": "=",
"version_value": "1909"
}
]
}
},
{
"product_name": "Advant OCS AC 100 OPS Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1"
},
{
"version_affected": "=",
"version_value": "6.0"
},
{
"version_affected": "=",
"version_value": "6.1"
}
]
}
}
]
},
"vendor_name": "ABB"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "For the Central Licensing Server component used in ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-275 Permission Issues"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "CONFIRM",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "CONFIRM",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-154-04"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-8471",
"datePublished": "2020-04-29T01:30:43",
"dateReserved": "2020-01-30T00:00:00",
"dateUpdated": "2024-08-04T10:03:44.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}