Details
A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.
Severity ?
8.3 (High)
{
"affected": [],
"aliases": [
"CVE-2025-41659"
],
"database_specific": {
"cwe_ids": [
"CWE-732"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-08-04T08:15:48Z",
"severity": "HIGH"
},
"details": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.",
"id": "GHSA-x97q-fjxx-pvxm",
"modified": "2025-08-04T09:30:28Z",
"published": "2025-08-04T09:30:28Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-41659"
},
{
"type": "WEB",
"url": "https://certvde.com/de/advisories/VDE-2025-051"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"type": "CVSS_V3"
}
]
}
CVE-2025-41659 (GCVE-0-2025-41659)
Vulnerability from cvelistv5 – Published: 2025-08-04 08:04 – Updated: 2025-08-04 16:35
VLAI?
EPSS
Summary
A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.
Severity ?
8.3 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CODESYS | Control RTE (SL) |
Affected:
0.0.0.0 , < 3.5.21.20
(semver)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Credits
Luca Borzacchiello from Nozomi Networks
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41659",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-04T16:34:47.316036Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T16:35:32.484Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.20",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.20",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.20",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.20",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.20",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.17.0.0",
"status": "affected",
"version": "0.0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Luca Borzacchiello from Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted.\u003cbr\u003e"
}
],
"value": "A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T08:04:04.597Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-051"
}
],
"source": {
"advisory": "VDE-2025-051",
"defect": [
"CERT@VDE#641801"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control PKI Exposure Enables Remote Certificate Access",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41659",
"datePublished": "2025-08-04T08:04:04.597Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-08-04T16:35:32.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…