GSD-2015-8214

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2015-8214",
    "description": "A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs\u0027 configuration was stored on their corresponding CPUs.",
    "id": "GSD-2015-8214"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2015-8214"
      ],
      "details": "A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs\u0027 configuration was stored on their corresponding CPUs.",
      "id": "GSD-2015-8214",
      "modified": "2023-12-13T01:20:03.369928Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2015-8214",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs\u0027 configuration was stored on their corresponding CPUs."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "78345",
            "refsource": "BID",
            "url": "http://www.securityfocus.com/bid/78345"
          },
          {
            "name": "1034279",
            "refsource": "SECTRACK",
            "url": "http://www.securitytracker.com/id/1034279"
          },
          {
            "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf",
            "refsource": "CONFIRM",
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf",
            "refsource": "CONFIRM",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:advanced:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tim_4r-ie_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tim_4r-ie_firmware:*:*:*:*:dnp3:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tim_4r-ie:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_firmware:*:*:*:*:lean:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_firmware:*:*:*:*:advanced:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tim_3v-ie_firmware:-:*:*:*:advanced:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tim_3v-ie_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tim_3v-ie_firmware:-:*:*:*:dnp3:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tim_3v-ie:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-8214"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions \u003c V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003c V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003c V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs\u0027 configuration was stored on their corresponding CPUs."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-264"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf"
            },
            {
              "name": "78345",
              "refsource": "BID",
              "tags": [],
              "url": "http://www.securityfocus.com/bid/78345"
            },
            {
              "name": "1034279",
              "refsource": "SECTRACK",
              "tags": [],
              "url": "http://www.securitytracker.com/id/1034279"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf",
              "refsource": "CONFIRM",
              "tags": [],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.7,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 9.5,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        }
      },
      "lastModifiedDate": "2021-04-22T21:15Z",
      "publishedDate": "2015-11-27T15:59Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…