GSD-2018-13366
Vulnerability from gsd - Updated: 2023-12-13 01:22Details
An information disclosure vulnerability in Fortinet FortiOS 6.0.1, 5.6.7 and below allows attacker to reveals serial number of FortiGate via hostname field defined in connection control setup packets of PPTP protocol.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2018-13366",
"description": "An information disclosure vulnerability in Fortinet FortiOS 6.0.1, 5.6.7 and below allows attacker to reveals serial number of FortiGate via hostname field defined in connection control setup packets of PPTP protocol.",
"id": "GSD-2018-13366"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2018-13366"
],
"details": "An information disclosure vulnerability in Fortinet FortiOS 6.0.1, 5.6.7 and below allows attacker to reveals serial number of FortiGate via hostname field defined in connection control setup packets of PPTP protocol.",
"id": "GSD-2018-13366",
"modified": "2023-12-13T01:22:26.687747Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2018-13366",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Fortinet FortiOS",
"version": {
"version_data": [
{
"version_value": "6.0.1"
},
{
"version_value": "5.6.7 and below"
}
]
}
}
]
},
"vendor_name": "Fortinet"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An information disclosure vulnerability in Fortinet FortiOS 6.0.1, 5.6.7 and below allows attacker to reveals serial number of FortiGate via hostname field defined in connection control setup packets of PPTP protocol."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/advisory/FG-IR-18-101",
"refsource": "CONFIRM",
"url": "https://fortiguard.com/advisory/FG-IR-18-101"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.6.7",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:fortinet:fortios:6.0.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:fortinet:fortios:6.0.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2018-13366"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An information disclosure vulnerability in Fortinet FortiOS 6.0.1, 5.6.7 and below allows attacker to reveals serial number of FortiGate via hostname field defined in connection control setup packets of PPTP protocol."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/advisory/FG-IR-18-101",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://fortiguard.com/advisory/FG-IR-18-101"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
},
"lastModifiedDate": "2019-04-10T13:53Z",
"publishedDate": "2019-04-09T17:29Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…