gsd-2018-13813
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2018-13813", "description": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2018-13813" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-13813" ], "details": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2018-13813", "modified": "2023-12-13T01:22:27.143810Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-13813", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "version": { "version_data": [ { "version_value": "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions \u003c V15 Update 4" }, { "version_value": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" : All versions \u003c V15 Update 4" }, { "version_value": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions \u003c V15 Update 4" }, { "version_value": "SIMATIC WinCC Runtime Advanced : All versions \u003c V15 Update 4" }, { "version_value": "SIMATIC WinCC Runtime Professional : All versions \u003c V15 Update 4" }, { "version_value": "SIMATIC WinCC (TIA Portal) : All versions \u003c V15 Update 4" }, { "version_value": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "105922", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105922" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "15.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-13813" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-601" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf" }, { "name": "105922", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105922" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.2 } }, "lastModifiedDate": "2019-10-09T23:34Z", "publishedDate": "2018-12-13T16:29Z" } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.