gsd-2018-5459
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2018-5459",
    "description": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.",
    "id": "GSD-2018-5459"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2018-5459"
      ],
      "details": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.",
      "id": "GSD-2018-5459",
      "modified": "2023-12-13T01:22:40.128086Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2018-5459",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "WAGO PFC200 Series",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "WAGO PFC200 Series"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-287"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01",
            "refsource": "MISC",
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "02.07.07\\(10\\)",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8206\\/025-001:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8207:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8207\\/025-000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8207\\/025-001:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8202:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/025-001:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8206:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8208\\/025-000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/025-002:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/040-001:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8203:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8203\\/025-000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/025-000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8204\\/025-000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8206\\/025-000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:750-8208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2018-5459"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2019-10-09T23:41Z",
      "publishedDate": "2018-02-13T21:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.