GSD-2019-11061

Vulnerability from gsd - Updated: 2023-12-13 01:24
Details
A broken access control vulnerability in HG100 firmware versions up to 4.00.06 allows an attacker in the same local area network to control IoT devices that connect with itself via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2019-11061",
    "description": "A broken access control vulnerability in HG100 firmware versions up to 4.00.06 allows an attacker in the same local area network to control IoT devices that connect with itself via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).",
    "id": "GSD-2019-11061"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2019-11061"
      ],
      "details": "A broken access control vulnerability in HG100 firmware versions up to 4.00.06 allows an attacker in the same local area network to control IoT devices that connect with itself via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).",
      "id": "GSD-2019-11061",
      "modified": "2023-12-13T01:24:02.598579Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@cert.org.tw",
        "DATE_PUBLIC": "2019-08-20T16:00:00.000Z",
        "ID": "CVE-2019-11061",
        "STATE": "PUBLIC",
        "TITLE": "HG100 has a broken access control vulnerability in its Web API Server"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "HG100 firmware",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "up to 4.00.0.6"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "ASUS"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "timhuang"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A broken access control vulnerability in HG100 firmware versions up to 4.00.06 allows an attacker in the same local area network to control IoT devices that connect with itself via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H)."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.0"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "Boken Access Control"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://tvn.twcert.org.tw/taiwanvn/TVN-201906003",
            "refsource": "CONFIRM",
            "url": "https://tvn.twcert.org.tw/taiwanvn/TVN-201906003"
          },
          {
            "name": "http://surl.twcert.org.tw/5df6x",
            "refsource": "CONFIRM",
            "url": "http://surl.twcert.org.tw/5df6x"
          },
          {
            "name": "https://github.com/tim124058/ASUS-SmartHome-Exploit/",
            "refsource": "CONFIRM",
            "url": "https://github.com/tim124058/ASUS-SmartHome-Exploit/"
          }
        ]
      },
      "source": {
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:asus:hg100_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.00.09",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:asus:hg100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@cert.org.tw",
          "ID": "CVE-2019-11061"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A broken access control vulnerability in HG100 firmware versions up to 4.00.06 allows an attacker in the same local area network to control IoT devices that connect with itself via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/tim124058/ASUS-SmartHome-Exploit/",
              "refsource": "CONFIRM",
              "tags": [
                "Exploit",
                "Third Party Advisory"
              ],
              "url": "https://github.com/tim124058/ASUS-SmartHome-Exploit/"
            },
            {
              "name": "https://tvn.twcert.org.tw/taiwanvn/TVN-201906003",
              "refsource": "CONFIRM",
              "tags": [
                "Exploit",
                "Third Party Advisory"
              ],
              "url": "https://tvn.twcert.org.tw/taiwanvn/TVN-201906003"
            },
            {
              "name": "http://surl.twcert.org.tw/5df6x",
              "refsource": "CONFIRM",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "http://surl.twcert.org.tw/5df6x"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 6.5,
          "impactScore": 4.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.0"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.2
        }
      },
      "lastModifiedDate": "2020-08-24T17:37Z",
      "publishedDate": "2019-08-29T01:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…