Details
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-13924", "description": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (all versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (all versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.", "id": "GSD-2019-13924" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-13924" ], "details": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.", "id": "GSD-2019-13924", "modified": "2023-12-13T01:23:41.557713Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13924", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE S602", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE S612", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE S623", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE S627-2M", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c 5.2.4" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X-200RNA switch family", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2.7" } ] } }, { "product_name": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c 4.1.3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-693: Protection Mechanism Failure" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13924" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-693" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07", "refsource": "MISC", "tags": [], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.5 } }, "lastModifiedDate": "2022-12-13T17:15Z", "publishedDate": "2020-02-11T16:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.