GSD-2019-8266

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2019-8266",
    "description": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.",
    "id": "GSD-2019-8266"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2019-8266"
      ],
      "details": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.",
      "id": "GSD-2019-8266",
      "modified": "2023-12-13T01:23:48.742580Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "vulnerability@kaspersky.com",
        "DATE_PUBLIC": "2019-03-01T00:00:00",
        "ID": "CVE-2019-8266",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "UltraVNC",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "1.2.2.3"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Kaspersky Lab"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-788: Access of Memory Location After End of Buffer"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/",
            "refsource": "MISC",
            "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
            "refsource": "CONFIRM",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
          },
          {
            "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
            "refsource": "MISC",
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "1.2.2.3",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnerability@kaspersky.com",
          "ID": "CVE-2019-8266"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-125"
                },
                {
                  "lang": "en",
                  "value": "CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-013-ultravnc-access-of-memory-location-after-end-of-buffer/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
              "refsource": "CONFIRM",
              "tags": [],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
              "refsource": "MISC",
              "tags": [],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2020-06-12T21:15Z",
      "publishedDate": "2019-03-08T23:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…