gsd-2020-3549
Vulnerability from gsd
Modified
2023-12-13 01:22
Details
A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2020-3549", "description": "A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device.", "id": "GSD-2020-3549" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-3549" ], "details": "A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device.", "id": "GSD-2020-3549", "modified": "2023-12-13T01:22:10.108216Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-10-21T16:00:00", "ID": "CVE-2020-3549", "STATE": "PUBLIC", "TITLE": "Cisco Firepower Management Center Software and Firepower Threat Defense Software sftunnel Pass the Hash Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Firepower Management Center ", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device." } ] }, "exploit": [ { "lang": "eng", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. " } ], "impact": { "cvss": { "baseScore": "8.1", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H ", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-326" } ] } ] }, "references": { "reference_data": [ { "name": "20201021 Cisco Firepower Management Center Software and Firepower Threat Defense Software sftunnel Pass the Hash Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftdfmc-sft-mitm-tc8AzFs2" } ] }, "source": { "advisory": "cisco-sa-ftdfmc-sft-mitm-tc8AzFs2", "defect": [ [ "CSCvp56719" ] ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.6.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firepower_threat_defense:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.6.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2020-3549" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-326" } ] } ] }, "references": { "reference_data": [ { "name": "20201021 Cisco Firepower Management Center Software and Firepower Threat Defense Software sftunnel Pass the Hash Vulnerability", "refsource": "CISCO", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftdfmc-sft-mitm-tc8AzFs2" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9 } }, "lastModifiedDate": "2020-10-30T13:21Z", "publishedDate": "2020-10-21T19:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.