gsd-2021-20657
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or alter the setting information without the access privilege via unspecified vectors.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-20657", "description": "Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or alter the setting information without the access privilege via unspecified vectors.", "id": "GSD-2021-20657" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-20657" ], "details": "Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or alter the setting information without the access privilege via unspecified vectors.", "id": "GSD-2021-20657", "modified": "2023-12-13T01:23:12.774623Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2021-20657", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SolarView Compact", "version": { "version_data": [ { "version_value": "SV-CPT-MC310 prior to Ver.6.5" } ] } } ] }, "vendor_name": "Contec Co., Ltd." } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or alter the setting information without the access privilege via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.contec.com/jp/api/downloadlogger?download=https://www.contec.com/jp/-/media/contec/jp/support/security-info/contec_security_solarview_210216.pdf", "refsource": "MISC", "url": "https://www.contec.com/jp/api/downloadlogger?download=https://www.contec.com/jp/-/media/contec/jp/support/security-info/contec_security_solarview_210216.pdf" }, { "name": "https://www.contec.com/jp/download/contract/contract2/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e\u0026downloaditemid=fa248fba-8901-4d9e-8212-b139f2defbdf", "refsource": "MISC", "url": "https://www.contec.com/jp/download/contract/contract2/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e\u0026downloaditemid=fa248fba-8901-4d9e-8212-b139f2defbdf" }, { "name": "https://jvn.jp/en/jp/JVN37417423/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/jp/JVN37417423/index.html" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:contec:sv-cpt-mc310_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.5", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:contec:sv-cpt-mc310:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2021-20657" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or alter the setting information without the access privilege via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-863" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.contec.com/jp/api/downloadlogger?download=https://www.contec.com/jp/-/media/contec/jp/support/security-info/contec_security_solarview_210216.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.contec.com/jp/api/downloadlogger?download=https://www.contec.com/jp/-/media/contec/jp/support/security-info/contec_security_solarview_210216.pdf" }, { "name": "https://www.contec.com/jp/download/contract/contract2/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e\u0026downloaditemid=fa248fba-8901-4d9e-8212-b139f2defbdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.contec.com/jp/download/contract/contract2/?itemid=b28c8b7c-9f40-40b2-843c-b5b04c035b0e\u0026downloaditemid=fa248fba-8901-4d9e-8212-b139f2defbdf" }, { "name": "https://jvn.jp/en/jp/JVN37417423/index.html", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/jp/JVN37417423/index.html" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 5.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.5 } }, "lastModifiedDate": "2021-03-01T17:00Z", "publishedDate": "2021-02-24T12:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.