Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-22277", "description": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.", "id": "GSD-2021-22277" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-22277" ], "details": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.", "id": "GSD-2021-22277", "modified": "2023-12-13T01:23:24.438944Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "DATE_PUBLIC": "2022-02-17T10:33:00.000Z", "ID": "CVE-2021-22277", "STATE": "PUBLIC", "TITLE": "AC 800M MMS - Denial of Service vulnerability in MMS communication" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "800xA, Control Software for AC 800M", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "5.1.0-0" }, { "version_affected": "\u003c=", "version_value": "5.1.0-3" }, { "version_affected": "\u003e=", "version_value": "5.1.1-0" }, { "version_affected": "\u003c=", "version_value": "5.1.1-4" }, { "version_affected": "\u003e=", "version_value": "6.0.0-0" }, { "version_affected": "\u003c=", "version_value": "6.0.0-3" }, { "version_affected": "\u003e=", "version_value": "6.1.0-0" }, { "version_affected": "\u003c=", "version_value": "6.1.1-1" } ] } }, { "product_name": "Control Builder Safe", "version": { "version_data": [ { "version_affected": "=", "version_value": "1.x" }, { "version_affected": "=", "version_value": "2.0" }, { "version_affected": "=", "version_value": "3.0" } ] } }, { "product_name": "Compact Product Suite - Control and I/O", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "5.1.0-0" }, { "version_affected": "\u003c=", "version_value": "5.1.0-3" }, { "version_affected": "\u003e=", "version_value": "5.1.1-0" }, { "version_affected": "\u003c=", "version_value": "5.1.1-4" }, { "version_affected": "\u003e=", "version_value": "6.0.0-0" }, { "version_affected": "\u003c=", "version_value": "6.0.0-3" }, { "version_affected": "\u003e=", "version_value": "6.1.0-0" }, { "version_affected": "\u003c=", "version_value": "6.1.1-1" } ] } }, { "product_name": "ABB Base Software for SoftControl", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "5.1.0-0" }, { "version_affected": "\u003c=", "version_value": "5.1.0-3" }, { "version_affected": "\u003e=", "version_value": "5.1.1-0" }, { "version_affected": "\u003c=", "version_value": "5.1.1-4" }, { "version_affected": "\u003e=", "version_value": "6.0.0-0" }, { "version_affected": "\u003c=", "version_value": "6.0.0-3" }, { "version_affected": "\u003e=", "version_value": "6.1.0-0" }, { "version_affected": "\u003c=", "version_value": "6.1.1-1" } ] } } ] }, "vendor_name": "ABB" } ] } }, "credit": [ { "lang": "eng", "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "MISC", "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:abb:800xa:*:*:*:*:*:*:ac_800m:*", "cpe_name": [], "versionEndIncluding": "5.1.0-3", "versionStartIncluding": "5.1.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:800xa:*:*:*:*:*:*:ac_800m:*", "cpe_name": [], "versionEndIncluding": "5.1.1-4", "versionStartIncluding": "5.1.1-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:800xa:*:*:*:*:*:*:ac_800m:*", "cpe_name": [], "versionEndExcluding": "6.0.0-4", "versionStartIncluding": "6.0.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:800xa:*:*:*:*:*:*:ac_800m:*", "cpe_name": [], "versionEndExcluding": "6.1.1-2", "versionStartIncluding": "6.1.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*", "cpe_name": [], "versionEndIncluding": "5.1.0-3", "versionStartIncluding": "5.1.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*", "cpe_name": [], "versionEndIncluding": "5.1.1-4", "versionStartIncluding": "5.1.1-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*", "cpe_name": [], "versionEndIncluding": "6.0.0-3", "versionStartIncluding": "6.0.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:base_software:*:*:*:*:*:softcontrol:*:*", "cpe_name": [], "versionEndIncluding": "6.1.1-1", "versionStartIncluding": "6.1.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:compact_product_suite:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.1.0-3", "versionStartIncluding": "5.1.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:compact_product_suite:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.1.1-4", "versionStartIncluding": "5.1.1-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:compact_product_suite:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.0.0-3", "versionStartIncluding": "6.0.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:compact_product_suite:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.1.1-1", "versionStartIncluding": "6.1.0-0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:abb:control_builder_safe:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "ID": "CVE-2021-22277" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-04-11T14:54Z", "publishedDate": "2022-04-01T23:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.