GSD-2021-23288

Vulnerability from gsd - Updated: 2023-12-13 01:23
Details
The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2021-23288",
    "description": "The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69.",
    "id": "GSD-2021-23288"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-23288"
      ],
      "details": "The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69.",
      "id": "GSD-2021-23288",
      "modified": "2023-12-13T01:23:29.921265Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "CybersecurityCOE@eaton.com",
        "DATE_PUBLIC": "2022-02-08T11:20:00.000Z",
        "ID": "CVE-2021-23288",
        "STATE": "PUBLIC",
        "TITLE": "Security issues in Intelligent Power Protector"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Intelligent Power Protector",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_value": "1.69"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Eaton"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Eaton thanks the below researchers for the coordinated support on the security vulnerabilities: - \u2022 CVE-2021-23288 \u2013 Andreas Finstad and Arthur Donkers"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.6,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:N/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-79 Cross-site Scripting (XSS)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf",
            "refsource": "MISC",
            "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf"
          }
        ]
      },
      "solution": [
        {
          "lang": "eng",
          "value": "Eaton has patched these security issues and new versions of the affected software are released. The latest versions can be downloaded from below location: -\nEaton IPM v1.69 \u2013 https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-intelligent-power-protector.resources.html"
        }
      ],
      "source": {
        "advisory": "ETN-VA-2021-1002b",
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:eaton:intelligent_power_protector:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "1.69",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "CybersecurityCOE@eaton.com",
          "ID": "CVE-2021-23288"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Protector-Vulnerability-Advisory_1002b_V1.0.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "NONE",
            "baseScore": 2.3,
            "confidentialityImpact": "NONE",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:A/AC:M/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 4.4,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "LOW",
          "userInteractionRequired": true
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 1.7,
          "impactScore": 2.7
        }
      },
      "lastModifiedDate": "2022-04-09T00:40Z",
      "publishedDate": "2022-04-01T23:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…