A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2021-40360",
    "description": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 and earlier (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.",
    "id": "GSD-2021-40360"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-40360"
      ],
      "details": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.",
      "id": "GSD-2021-40360",
      "modified": "2023-12-13T01:23:25.244822Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2021-40360",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "SIMATIC PCS 7 V8.2",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC PCS 7 V9.0",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC PCS 7 V9.1",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V9.1 SP1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinCC V15 and earlier",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V15 SP1 Update 7"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinCC V16",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V16 Update 5"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinCC V17",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V17 Update 2"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinCC V7.4",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V7.4 SP1 Update 19"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinCC V7.5",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "All versions \u003c V7.5 SP2 Update 6"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "8.2",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:14.0.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:13:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.4",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:17:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:13:sp2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update5:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_6:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_5:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update14:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update15:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update16:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update17:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update18:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-40360"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-522"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
              "refsource": "MISC",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-07-17T15:15Z",
      "publishedDate": "2022-02-09T16:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.