gsd-2021-41769
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-41769", "description": "A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions \u003c V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.", "id": "GSD-2021-41769" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-41769" ], "details": "A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions \u003c V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.", "id": "GSD-2021-41769", "modified": "2023-12-13T01:23:27.101806Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-41769", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIPROTEC 5 6MD85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 6MD86 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 6MD89 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 6MU85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7KE85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SA82 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SA86 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SA87 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SD82 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SD86 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SD87 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SJ81 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SJ82 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SJ85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SJ86 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SK82 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SK85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SL82 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SL86 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SL87 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SS85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7ST85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7SX85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7UM85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7UT82 devices (CPU variant CP100)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7UT85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7UT86 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7UT87 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7VE85 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 7VK87 devices (CPU variant CP300)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } }, { "product_name": "SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050)", "version": { "version_data": [ { "version_value": "All versions \u003c V8.83" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions \u003c V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-439673.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-439673.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6md85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6md86_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6md89_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6md89:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:6mu85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6mu85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ke85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ke85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sa82_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sa86_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sa87_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sd82_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sd86_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sd87_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sj81_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sj81:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sj82_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sj85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sj86_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sk82_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sk85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sl82_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sl86_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sl87_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ss85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ss85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7st85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7st85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sx800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sx800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7sx85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7sx85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7um85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ut82_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ut85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ut86_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ut87_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7ve85_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7ve85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:7vk87_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.83", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-41769" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions \u003c V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions \u003c V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions \u003c V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-439673.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-439673.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-01-19T16:49Z", "publishedDate": "2022-01-11T12:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.