In the Linux kernel, the following vulnerability has been resolved:
hwmon: (lm90) Prevent integer overflow/underflow in hysteresis calculations
Commit b50aa49638c7 ("hwmon: (lm90) Prevent integer underflows of
temperature calculations") addressed a number of underflow situations
when writing temperature limits. However, it missed one situation, seen
when an attempt is made to set the hysteresis value to MAX_LONG and the
critical temperature limit is negative.
Use clamp_val() when setting the hysteresis temperature to ensure that
the provided value can never overflow or underflow.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-47098" ], "details": "In the Linux kernel, the following vulnerability has been resolved:\n\nhwmon: (lm90) Prevent integer overflow/underflow in hysteresis calculations\n\nCommit b50aa49638c7 (\"hwmon: (lm90) Prevent integer underflows of\ntemperature calculations\") addressed a number of underflow situations\nwhen writing temperature limits. However, it missed one situation, seen\nwhen an attempt is made to set the hysteresis value to MAX_LONG and the\ncritical temperature limit is negative.\n\nUse clamp_val() when setting the hysteresis temperature to ensure that\nthe provided value can never overflow or underflow.", "id": "GSD-2021-47098", "modified": "2024-03-01T06:04:48.321324Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@kernel.org", "ID": "CVE-2021-47098", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "b50aa49638c7", "version_value": "d105f30bea91" }, { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "5.14" }, { "lessThan": "5.14", "status": "unaffected", "version": "0", "versionType": "custom" }, { "lessThanOrEqual": "5.15.*", "status": "unaffected", "version": "5.15.12", "versionType": "custom" }, { "lessThanOrEqual": "*", "status": "unaffected", "version": "5.16", "versionType": "original_commit_for_fix" } ] } } ] } } ] }, "vendor_name": "Linux" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In the Linux kernel, the following vulnerability has been resolved:\n\nhwmon: (lm90) Prevent integer overflow/underflow in hysteresis calculations\n\nCommit b50aa49638c7 (\"hwmon: (lm90) Prevent integer underflows of\ntemperature calculations\") addressed a number of underflow situations\nwhen writing temperature limits. However, it missed one situation, seen\nwhen an attempt is made to set the hysteresis value to MAX_LONG and the\ncritical temperature limit is negative.\n\nUse clamp_val() when setting the hysteresis temperature to ensure that\nthe provided value can never overflow or underflow." } ] }, "generator": { "engine": "bippy-4986f5686161" }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://git.kernel.org/stable/c/d105f30bea9104c590a9e5b495cb8a49bdfe405f", "refsource": "MISC", "url": "https://git.kernel.org/stable/c/d105f30bea9104c590a9e5b495cb8a49bdfe405f" }, { "name": "https://git.kernel.org/stable/c/55840b9eae5367b5d5b29619dc2fb7e4596dba46", "refsource": "MISC", "url": "https://git.kernel.org/stable/c/55840b9eae5367b5d5b29619dc2fb7e4596dba46" } ] } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "In the Linux kernel, the following vulnerability has been resolved:\n\nhwmon: (lm90) Prevent integer overflow/underflow in hysteresis calculations\n\nCommit b50aa49638c7 (\"hwmon: (lm90) Prevent integer underflows of\ntemperature calculations\") addressed a number of underflow situations\nwhen writing temperature limits. However, it missed one situation, seen\nwhen an attempt is made to set the hysteresis value to MAX_LONG and the\ncritical temperature limit is negative.\n\nUse clamp_val() when setting the hysteresis temperature to ensure that\nthe provided value can never overflow or underflow." } ], "id": "CVE-2021-47098", "lastModified": "2024-03-05T13:41:01.900", "metrics": {}, "published": "2024-03-04T18:15:08.090", "references": [ { "source": "416baaa9-dc9f-4396-8d5f-8c081fb06d67", "url": "https://git.kernel.org/stable/c/55840b9eae5367b5d5b29619dc2fb7e4596dba46" }, { "source": "416baaa9-dc9f-4396-8d5f-8c081fb06d67", "url": "https://git.kernel.org/stable/c/d105f30bea9104c590a9e5b495cb8a49bdfe405f" } ], "sourceIdentifier": "416baaa9-dc9f-4396-8d5f-8c081fb06d67", "vulnStatus": "Awaiting Analysis" } } } }
Loading...