gsd-2022-2081
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-2081", "id": "GSD-2022-2081" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-2081" ], "details": "A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.", "id": "GSD-2022-2081", "modified": "2023-12-13T01:19:20.373020Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "ID": "CVE-2022-2081", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RTU500 series CMU firmware", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "12.0.1.0", "version_value": "12.0.13.0" }, { "version_affected": "\u003c=", "version_name": "12.2.1.0", "version_value": "12.2.11.0" }, { "version_affected": "\u003c=", "version_name": "12.4.1.0", "version_value": "12.4.11.0" }, { "version_affected": "\u003c=", "version_name": "12.6.1.0", "version_value": "12.6.7.0" }, { "version_affected": "\u003c=", "version_name": "12.7.1.0", "version_value": "12.7.3.0" }, { "version_affected": "\u003c=", "version_name": "13.2.1.0", "version_value": "13.2.4.0" }, { "version_affected": "=", "version_value": "13.3.1.0" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-120", "lang": "eng", "value": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000111\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "MISC", "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000111\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5E23735-DB56-4C1E-8389-B06018CC4D9E", "versionEndIncluding": "12.0.13", "versionStartIncluding": "12.0.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2469A78A-6F37-4F4B-BED8-060914B2D0A4", "versionEndIncluding": "12.2.11", "versionStartIncluding": "12.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9E6934B-EBB2-45FB-8E4A-7D360CBA0F92", "versionEndIncluding": "12.4.11", "versionStartIncluding": "12.4.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8966632-8645-43D6-AB52-8BC1C1BDB6DD", "versionEndIncluding": "12.6.7", "versionStartIncluding": "12.6.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F12F1A20-9D3C-4F2B-B538-8B4EABD288C9", "versionEndIncluding": "12.7.3", "versionStartIncluding": "12.7.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F7A0F9D4-E9ED-4351-8909-EEE689DE2BF4", "versionEndIncluding": "13.2.4", "versionStartIncluding": "13.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu520_firmware:13.3.1:*:*:*:*:*:*:*", "matchCriteriaId": "1621CAF4-C18A-48B5-82AC-F8D09105656A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*", "matchCriteriaId": "11AF93AD-200F-47A6-BA2C-F82165AFB50D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB001482-F203-4731-A6DD-6BCE3C1338CA", "versionEndIncluding": "12.0.13", "versionStartIncluding": "12.0.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79BC5D4A-09B2-41FB-962A-CF580181EB2C", "versionEndIncluding": "12.2.11", "versionStartIncluding": "12.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A30CDB2F-E0CC-4440-9E59-AB339F94996F", "versionEndIncluding": "12.4.11", "versionStartIncluding": "12.4.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56598D9D-5BCB-42C6-8705-AB79C4BD2A9A", "versionEndIncluding": "12.6.7", "versionStartIncluding": "12.6.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FDE92C-733F-4B52-8BE6-E37898B39075", "versionEndIncluding": "12.7.3", "versionStartIncluding": "12.7.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2209D1D9-94CD-4D8B-BB80-39CC129FEEF4", "versionEndIncluding": "13.2.4", "versionStartIncluding": "13.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu530_firmware:13.3.1:*:*:*:*:*:*:*", "matchCriteriaId": "BACEC63E-0548-483F-813E-C04F4C95970E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC6F9377-E6BB-4DEA-9D87-0AF792CBAC57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F1F7579-050B-4216-A4D5-FD74C8A19618", "versionEndIncluding": "12.0.13", "versionStartIncluding": "12.0.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "803838B5-058E-436B-8CE5-BF711456F96B", "versionEndIncluding": "12.2.11", "versionStartIncluding": "12.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0361A98-1496-4763-A489-DCAE0D0DF613", "versionEndIncluding": "12.4.11", "versionStartIncluding": "12.4.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "762AB8CE-068D-46D4-A275-154A2AC58E55", "versionEndIncluding": "12.6.7", "versionStartIncluding": "12.6.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DF9263A-D1DB-4899-99C2-88B59847C808", "versionEndIncluding": "12.7.3", "versionStartIncluding": "12.7.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15B3C46C-0A5E-4142-A096-94A513DD8004", "versionEndIncluding": "13.2.4", "versionStartIncluding": "13.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu540_firmware:13.3.1:*:*:*:*:*:*:*", "matchCriteriaId": "E8B2A709-9538-47C9-9E70-DBC1D2817E79", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*", "matchCriteriaId": "6EEFDEF0-883D-402B-9CD4-333A145E3C75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0708BD2D-FEA4-4C97-9C3A-B4E67EA3D926", "versionEndIncluding": "12.0.13", "versionStartIncluding": "12.0.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BDB5A36-9B2F-43F9-A81B-506C4660151F", "versionEndIncluding": "12.2.11", "versionStartIncluding": "12.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F25FBFD5-BC45-49C9-87D4-A9C05405490D", "versionEndIncluding": "12.4.11", "versionStartIncluding": "12.4.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0505DF4D-0B06-4E61-B756-C2B5D31B85A0", "versionEndIncluding": "12.6.7", "versionStartIncluding": "12.6.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9495E9A9-733C-4073-8B39-1A08A88B05A7", "versionEndIncluding": "12.7.3", "versionStartIncluding": "12.7.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "269F1D56-A575-487D-B5ED-4E774C26BA3B", "versionEndIncluding": "13.2.4", "versionStartIncluding": "13.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu560_firmware:13.3.1:*:*:*:*:*:*:*", "matchCriteriaId": "530437F6-6F90-45D5-821C-B87C292C0CCC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*", "matchCriteriaId": "495DCBD6-D2D1-4295-81D1-6ACA1B2CA223", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function." }, { "lang": "es", "value": "Existe una vulnerabilidad en la funci\u00f3n HCI Modbus TCP incluida en las versiones de producto enumeradas anteriormente. Si HCI Modbus TCP est\u00e1 habilitado y configurado, un atacante podr\u00eda aprovechar la vulnerabilidad enviando un mensaje especialmente manipulado a la RTU500 a alta velocidad, lo que provocar\u00eda que la CMU RTU500 objetivo se reiniciara. La vulnerabilidad se debe a una falta de control de inundaciones que eventualmente, si se explota, provoca un desbordamiento de pila interna en la funci\u00f3n HCI Modbus TCP." } ], "id": "CVE-2022-2081", "lastModified": "2024-01-10T16:39:45.477", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" } ] }, "published": "2024-01-04T10:15:10.927", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000111\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.