GSD-2022-2179
Vulnerability from gsd - Updated: 2023-12-13 01:19Details
The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-2179",
"description": "The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.",
"id": "GSD-2022-2179"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-2179"
],
"details": "The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.",
"id": "GSD-2022-2179",
"modified": "2023-12-13T01:19:19.664787Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
"ID": "CVE-2022-2179",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-188-01 Rockwell Automation MicroLogix Improper Restriction of Rendered UI Layers or Frames"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MicroLogix 1400",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "21.007"
}
]
}
},
{
"product_name": "MicroLogix 1100",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Rockwell Automation"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Pawan V. Sable and Pranita Binnar from Veermata Jijabai Technological Institute (VJTI) reported this vulnerability to Rockwell Automation."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-1021"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-188-01",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-188-01"
},
{
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1135994",
"refsource": "CONFIRM",
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1135994"
}
]
},
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "eng",
"value": "Rockwell Automation encourages those using the affected software to implement the mitigations below to minimize risk. Additionally, Rockwell Automation encourages users to combine risk mitigations with security best practices (also provided below) to deploy a defense-in-depth strategy.\n\n Disable the web server where possible (this component is an optional feature and disabling it will not disrupt the intended use of the device).\n Configure firewalls to disallow network communication through HTTP/Port 80\n\nIf applying the mitigations noted above are not possible, please see Rockwell Automation\u2019s Knowledgebase article QA43240 Security Best Practices.\n\nFor more information, please see the industrial security advisory from Rockwell Automation."
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "21.007",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-2179"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-1021"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-188-01",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-188-01"
},
{
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1135994",
"refsource": "CONFIRM",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1135994"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-07-27T21:45Z",
"publishedDate": "2022-07-20T16:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…