A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-29561", "id": "GSD-2022-29561" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-29561" ], "details": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.", "id": "GSD-2022-29561", "modified": "2023-12-13T01:19:42.385086Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-29561", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RUGGEDCOM ROX MX5000", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX MX5000RE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1400", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1500", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1501", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1510", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1511", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1512", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1524", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX1536", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } }, { "product_name": "RUGGEDCOM ROX RX5000", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V2.16.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user." } ] }, "impact": { "cvss": [ { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-352", "lang": "eng", "value": "CWE-352: Cross-Site Request Forgery (CSRF)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000re_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1501_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1510_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1511_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1512_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1524_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx1536_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rox_rx5000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-29561" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-352" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-07-18T16:05Z", "publishedDate": "2023-07-11T10:15Z" } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.