gsd-2022-29825
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-29825", "id": "GSD-2022-29825" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-29825" ], "details": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.", "id": "GSD-2022-29825", "modified": "2023-12-13T01:19:41.951355Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2022-29825", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "=", "version_value": "from 1.000A to 1.090U" } ] } }, { "product_name": "GT Designer3 Version1 (GOT2000)", "version": { "version_data": [ { "version_affected": "=", "version_value": "from 1.122C to 1.290C" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-259", "lang": "eng", "value": "CWE-259 Use of Hard-coded Password" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf" }, { "name": "https://jvn.jp/vu/JVNVU97244961/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU97244961/index.html" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "cpe_name": [], "versionStartIncluding": "1.087r", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.086q", "versionStartIncluding": "1.015r", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.011m", "versionStartIncluding": "1.000a", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2022-29825" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "https://jvn.jp/vu/JVNVU97244961/index.html", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://jvn.jp/vu/JVNVU97244961/index.html" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf", "refsource": "MISC", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05", "refsource": "MISC", "tags": [], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2023-05-31T09:15Z", "publishedDate": "2022-11-25T00:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.