GSD-2022-31481
Vulnerability from gsd - Updated: 2023-12-13 01:19Details
An unauthenticated attacker can send a specially crafted update file to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.302 for the LP series and 1.296 for the EP series. The overflowed data can allow the attacker to manipulate the “normal” code execution to that of their choosing. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-31481",
"description": "An unauthenticated attacker can send a specially crafted update file to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.302 for the LP series and 1.296 for the EP series. The overflowed data can allow the attacker to manipulate the \u201cnormal\u201d code execution to that of their choosing. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable.",
"id": "GSD-2022-31481"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-31481"
],
"details": "An unauthenticated attacker can send a specially crafted update file to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.302 for the LP series and 1.296 for the EP series. The overflowed data can allow the attacker to manipulate the \u201cnormal\u201d code execution to that of their choosing. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable.",
"id": "GSD-2022-31481",
"modified": "2023-12-13T01:19:17.797889Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productsecurity@carrier.com",
"DATE_PUBLIC": "2022-06-02T22:00:00.000Z",
"ID": "CVE-2022-31481",
"STATE": "PUBLIC",
"TITLE": "Remote Code Execution via buffer overflow in firmware update process"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LNL-X2210",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LNL-X2220",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LNL-X3300",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LNL-X4420",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LNL-4420",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.296"
}
]
}
},
{
"product_name": "S2-LP-1501",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "S2-LP-1502",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "S2-LP-2500",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "S2-LP-4502",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
}
]
},
"vendor_name": "LenelS2"
},
{
"product": {
"product_data": [
{
"product_name": "LP1501",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LP1502",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LP2500",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "LP4502",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.302"
}
]
}
},
{
"product_name": "EP4502",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "ALL",
"version_value": "1.296"
}
]
}
}
]
},
"vendor_name": "HID Mercury"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Sam Quinn @eAyeP and Steve Povolny @spovolny from Trellix Threat Labs"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated attacker can send a specially crafted update file to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.302 for the LP series and 1.296 for the EP series. The overflowed data can allow the attacker to manipulate the \u201cnormal\u201d code execution to that of their choosing. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120 Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.corporate.carrier.com/product-security/advisories-resources/",
"refsource": "MISC",
"url": "https://www.corporate.carrier.com/product-security/advisories-resources/"
}
]
},
"solution": [
{
"lang": "eng",
"value": "Update to the latest version of firmware"
}
],
"source": {
"advisory": "CARR-PSA-006-0522",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "eng",
"value": "Disable the controller\u0027s Web Server. \nWhen the controller is configured to disable web access, you cannot remotely login into the controller\u2019s web page.\n1. Login to controller web pages\n2. Go to \u201cUsers\u201d Tab\n3. Near bottom of the Users page, check option to \u201cDisable Web Server\u201d\n4. Then select \u201cSubmit\u201d at the bottom of the page\n5. Then select \u201cApply Settings\u201d tab\n6. And on that page, select button \u201cApply Settings, Reboot\u201d\nThe Controller will apply the new setting and reboot. Web login will be disabled until switch 1 is physically turned ON, on the controller."
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hidglobal:lp1501_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hidglobal:lp1501:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hidglobal:lp1502_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hidglobal:lp1502:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hidglobal:lp2500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hidglobal:lp2500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hidglobal:lp4502_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hidglobal:lp4502:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hidglobal:ep4502_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.296",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hidglobal:ep4502:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_lnl-4420_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.296",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_lnl-4420:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_lnl-x2210_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_lnl-x2210:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_lnl-x2220_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_lnl-x2220:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_lnl-x3300_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_lnl-x3300:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_lnl-x4420_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_lnl-x4420:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_s2-lp-1501_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_s2-lp-1501:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_s2-lp-1502_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_s2-lp-1502:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_s2-lp-2500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_s2-lp-2500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:carrier:lenels2_s2-lp-4502_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.302",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:carrier:lenels2_s2-lp-4502:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productsecurity@carrier.com",
"ID": "CVE-2022-31481"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An unauthenticated attacker can send a specially crafted update file to the device that can overflow a buffer. This vulnerability impacts products based on HID Mercury Intelligent Controllers LP1501, LP1502, LP2500, LP4502, and EP4502 which contain firmware versions prior to 1.302 for the LP series and 1.296 for the EP series. The overflowed data can allow the attacker to manipulate the \u201cnormal\u201d code execution to that of their choosing. An attacker with this level of access on the device can monitor all communications sent to and from this device, modify onboard relays, change configuration files, or cause the device to become unstable."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.corporate.carrier.com/product-security/advisories-resources/",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.corporate.carrier.com/product-security/advisories-resources/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0
}
},
"lastModifiedDate": "2022-06-17T14:31Z",
"publishedDate": "2022-06-06T17:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…