GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2022-31801

Vulnerability from gsd - Updated: 2023-12-13 01:19
Details
An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-31801",
    "description": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.",
    "id": "GSD-2022-31801"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-31801"
      ],
      "details": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.",
      "id": "GSD-2022-31801",
      "modified": "2023-12-13T01:19:18.048036Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "info@cert.vde.com",
        "DATE_PUBLIC": "2022-06-21T07:00:00.000Z",
        "ID": "CVE-2022-31801",
        "STATE": "PUBLIC",
        "TITLE": "Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "MULTIPROG",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "All Versions",
                          "version_value": "All Versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ProConOS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "All Versions",
                          "version_value": "All Versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ProConOS eCLR\t",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "All Versions",
                          "version_value": "All Versions"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "PHOENIX CONTACT"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "This vulnerability was reported by Forescout."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-345 Insufficient Verification of Data Authenticity"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert.vde.com/en/advisories/VDE-2022-026/",
            "refsource": "CONFIRM",
            "url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
          }
        ]
      },
      "source": {
        "advisory": "VDE-2022-026",
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:phoenixcontact:multiprog:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:phoenixcontact:proconos:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:phoenixcontact-software:proconos_eclr:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "ID": "CVE-2022-31801"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-345"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-026/",
              "refsource": "CONFIRM",
              "tags": [
                "Mitigation",
                "Third Party Advisory"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2022-06-28T17:45Z",
      "publishedDate": "2022-06-21T08:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…