A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.
Aliases
Aliases
{ GSD: { alias: "CVE-2022-34819", description: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.", id: "GSD-2022-34819", }, gsd: { metadata: { exploitCode: "unknown", remediation: "unknown", reportConfidence: "confirmed", type: "vulnerability", }, osvSchema: { aliases: [ "CVE-2022-34819", ], details: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.", id: "GSD-2022-34819", modified: "2023-12-13T01:19:18.924799Z", schema_version: "1.4.0", }, }, namespaces: { "cve.org": { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2022-34819", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC CP 1242-7 V2", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIMATIC CP 1243-1", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIMATIC CP 1243-7 LTE EU", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIMATIC CP 1243-7 LTE US", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIMATIC CP 1243-8 IRC", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIMATIC CP 1542SP-1 IRC", version: { version_data: [ { version_affected: "=", version_value: "All versions >= V2.0 < V2.2.28", }, ], }, }, { product_name: "SIMATIC CP 1543-1", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.0.22", }, ], }, }, { product_name: "SIMATIC CP 1543SP-1", version: { version_data: [ { version_affected: "=", version_value: "All versions >= V2.0 < V2.2.28", }, ], }, }, { product_name: "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL", version: { version_data: [ { version_affected: "=", version_value: "All versions >= V2.0 < V2.2.28", }, ], }, }, { product_name: "SIPLUS ET 200SP CP 1543SP-1 ISEC", version: { version_data: [ { version_affected: "=", version_value: "All versions >= V2.0 < V2.2.28", }, ], }, }, { product_name: "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL", version: { version_data: [ { version_affected: "=", version_value: "All versions >= V2.0 < V2.2.28", }, ], }, }, { product_name: "SIPLUS NET CP 1242-7 V2", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIPLUS NET CP 1543-1", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.0.22", }, ], }, }, { product_name: "SIPLUS S7-1200 CP 1243-1", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, { product_name: "SIPLUS S7-1200 CP 1243-1 RAIL", version: { version_data: [ { version_affected: "=", version_value: "All versions < V3.3.46", }, ], }, }, ], }, vendor_name: "Siemens", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.", }, ], }, impact: { cvss: [ { baseScore: 10, baseSeverity: "CRITICAL", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", version: "3.1", }, ], }, problemtype: { problemtype_data: [ { description: [ { cweId: "CWE-122", lang: "eng", value: "CWE-122: Heap-based Buffer Overflow", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf", }, ], }, }, "nvd.nist.gov": { configurations: { CVE_data_version: "4.0", nodes: [ { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "2.0", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "3.0.22", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "2.0", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "2.0", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "2.0", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionStartIncluding: "2.0", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "3.0.22", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*", cpe_name: [], vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, ], }, cve: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2022-34819", }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions < V3.3.46), SIMATIC CP 1243-1 (All versions < V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions < V3.3.46), SIMATIC CP 1243-7 LTE US (All versions < V3.3.46), SIMATIC CP 1243-8 IRC (All versions < V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0 < V2.2.28), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0 < V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0 < V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions < V3.3.46), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions < V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions < V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "en", value: "CWE-122", }, ], }, ], }, references: { reference_data: [ { name: "N/A", refsource: "CONFIRM", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf", }, ], }, }, impact: { baseMetricV2: { acInsufInfo: false, cvssV2: { accessComplexity: "MEDIUM", accessVector: "NETWORK", authentication: "NONE", availabilityImpact: "COMPLETE", baseScore: 9.3, confidentialityImpact: "COMPLETE", integrityImpact: "COMPLETE", vectorString: "AV:N/AC:M/Au:N/C:C/I:C/A:C", version: "2.0", }, exploitabilityScore: 8.6, impactScore: 10, obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, severity: "HIGH", userInteractionRequired: false, }, baseMetricV3: { cvssV3: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "HIGH", baseScore: 10, baseSeverity: "CRITICAL", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "CHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", version: "3.1", }, exploitabilityScore: 3.9, impactScore: 6, }, }, lastModifiedDate: "2023-03-14T10:15Z", publishedDate: "2022-07-12T10:15Z", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.