GSD-2022-41648

Vulnerability from gsd - Updated: 2023-12-13 01:19
Details
The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2022-41648",
    "id": "GSD-2022-41648"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-41648"
      ],
      "details": "The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line.",
      "id": "GSD-2022-41648",
      "modified": "2023-12-13T01:19:33.218241Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "DATE_PUBLIC": "2022-10-25T18:16:00.000Z",
        "ID": "CVE-2022-41648",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Controller TNC 640",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_name": "Version",
                          "version_value": "340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "HEIDENHAIN"
            }
          ]
        }
      },
      "credit": [
        {
          "lang": "eng",
          "value": "Marco Balduzzi of Trend Micro reported this vulnerability."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-287 Improper Authentication"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-02",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-02"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:heidenhain:heros:5.08.3:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:heidenhain:tnc_640_programming_station:340590_07:sp5:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:heidenhain:tnc_640:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-41648"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-02",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-02"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2022-11-03T14:02Z",
      "publishedDate": "2022-10-28T18:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…