gsd-2022-45857
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-45857", "description": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted.", "id": "GSD-2022-45857" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-45857" ], "details": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted.", "id": "GSD-2022-45857", "modified": "2023-12-13T01:19:24.723674Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2022-45857", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FortiManager", "version": { "version_data": [ { "version_affected": "=", "version_value": "7.0.0" }, { "version_affected": "=", "version_value": "6.4.0" }, { "version_affected": "=", "version_value": "6.2.0" } ] } } ] }, "vendor_name": "Fortinet" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted." } ] }, "impact": { "cvss": [ { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:H/E:F/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-286", "lang": "eng", "value": "Improper access control" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-22-371", "refsource": "MISC", "url": "https://fortiguard.com/psirt/FG-IR-22-371" } ] }, "solution": [ { "lang": "en", "value": "Please upgrade to FortiManager version 7.0.2 or above\r\nPlease upgrade to FortiManager version 6.4.8 or above\r\nPlease upgrade to FortiManager version 6.2.9 or above" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.4.8", "versionStartIncluding": "6.4.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.0.2", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.2.9", "versionStartIncluding": "6.2.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2022-45857" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-22-371", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-22-371" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 5.3 } }, "lastModifiedDate": "2023-01-11T17:23Z", "publishedDate": "2023-01-05T08:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.