gsd-2022-4608
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-4608", "id": "GSD-2022-4608" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-4608" ], "details": "A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.", "id": "GSD-2022-4608", "modified": "2023-12-13T01:19:15.876588Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "ID": "CVE-2022-4608", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RTU500 series", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "unaffected", "versions": [ { "status": "affected", "version": "RTU500 series CMU Firmware version 13.3.1" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 13.3.2" }, { "status": "unaffected", "version": "RTU500 series CMU Firmware version 13.3.3" }, { "status": "unaffected", "version": "RTU500 series CMU Firmware version 13.4.1" } ] } } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "configuration": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nRTU500 series with HCI IEC 60870-5-104 and IEC 62351-3 configured and enabled.\n\n\u003cbr\u003e" } ], "value": "\nRTU500 series with HCI IEC 60870-5-104 and IEC 62351-3 configured and enabled.\n\n\n" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-120", "lang": "eng", "value": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "MISC", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nUpdate to CMU Firmware versions 13.3.3 or 13.4.1.\n\n\u003cbr\u003e" } ], "value": "\nUpdate to CMU Firmware versions 13.3.3 or 13.4.1.\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nDisable the HCI IEC 60870-5-104 function or its IEC 62351-3 feature if it is not used.\n\n\u003cbr\u003e" } ], "value": "\nDisable the HCI IEC 60870-5-104 function or its IEC 62351-3 feature if it is not used.\n\n\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.4.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "ID": "CVE-2022-4608" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2023-08-03T14:51Z", "publishedDate": "2023-07-26T06:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.