cve-2022-4608
Vulnerability from cvelistv5
Published
2023-07-26 05:26
Modified
2024-09-24 15:33
Severity ?
EPSS score ?
Summary
A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Hitachi Energy | RTU500 series |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T01:41:45.792Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "RTU500 series", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "RTU500 series CMU Firmware version 13.3.1" }, { "status": "affected", "version": "RTU500 series CMU Firmware version 13.3.2" }, { "status": "unaffected", "version": "RTU500 series CMU Firmware version 13.3.3" }, { "status": "unaffected", "version": "RTU500 series CMU Firmware version 13.4.1" } ] } ], "configurations": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "RTU500 series with HCI IEC 60870-5-104 and IEC 62351-3 configured and enabled.\n\n\u003cbr\u003e" } ], "value": "RTU500 series with HCI IEC 60870-5-104 and IEC 62351-3 configured and enabled." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow." } ], "value": "A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow." } ], "impacts": [ { "capecId": "CAPEC-100", "descriptions": [ { "lang": "en", "value": "CAPEC-100 Overflow Buffers" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-24T15:33:42.351Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Update to CMU Firmware versions 13.3.3 or 13.4.1.\n\n\u003cbr\u003e" } ], "value": "Update to CMU Firmware versions 13.3.3 or 13.4.1." } ], "source": { "discovery": "UNKNOWN" }, "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Disable the HCI IEC 60870-5-104 function or its IEC 62351-3 feature if it is not used.\n\n\u003cbr\u003e" } ], "value": "Disable the HCI IEC 60870-5-104 function or its IEC 62351-3 feature if it is not used." } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-4608", "datePublished": "2023-07-26T05:26:42.720Z", "dateReserved": "2022-12-19T09:46:30.033Z", "dateUpdated": "2024-09-24T15:33:42.351Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-4608\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2023-07-26T06:15:10.220\",\"lastModified\":\"2024-09-25T01:15:33.067\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C444DE8E-5AC5-409B-8DA0-5C49A69076DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C55747C-E5DA-4444-B017-1994011A5EF7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:13.3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0997C03B-21AC-4767-856C-79833FB378A8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:13.4.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C0763F03-C6C8-4104-9028-3CF265F289D5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE94252D-03EE-451B-8322-B4DBC790C6E9\"}]}]}],\"references\":[{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000121\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@hitachienergy.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.