gsd-2023-25957
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. For compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `'Use Encryption'` is disabled.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-25957",
    "id": "GSD-2023-25957"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-25957"
      ],
      "details": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.16.4 \u003c V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.2.0 \u003c V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application.\r\n\r\nFor compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `\u0027Use Encryption\u0027` is disabled.",
      "id": "GSD-2023-25957",
      "modified": "2023-12-13T01:20:40.541915Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2023-25957",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Mendix SAML (Mendix 7 compatible)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003e= V1.16.4 \u003c V1.17.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Mendix SAML (Mendix 8 compatible)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003e= V2.2.0 \u003c V2.3.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Mendix SAML (Mendix 9 latest compatible, New Track)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003e= V3.1.9 \u003c V3.3.1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Mendix SAML (Mendix 9 latest compatible, Upgrade Track)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003e= V3.1.8 \u003c V3.3.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Mendix SAML (Mendix 9.6 compatible, New Track)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003e= V3.1.9 \u003c V3.2.7"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Mendix SAML (Mendix 9.6 compatible, Upgrade Track)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003e= V3.1.8 \u003c V3.2.6"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.16.4 \u003c V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.2.0 \u003c V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application.\r\n\r\nFor compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `\u0027Use Encryption\u0027` is disabled."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-303",
                "lang": "eng",
                "value": "CWE-303: Incorrect Implementation of Authentication Algorithm"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:mendix:saml:*:*:*:*:*:mendix:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.2.5",
                "versionStartIncluding": "3.1.9",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:mendix:saml:*:*:*:*:*:mendix:*:*",
                "cpe_name": [],
                "versionEndExcluding": "2.2.3",
                "versionStartIncluding": "2.2.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:mendix:saml:*:*:*:*:*:mendix:*:*",
                "cpe_name": [],
                "versionEndExcluding": "1.17.2",
                "versionStartIncluding": "1.16.4",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2023-25957"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.16.4 \u003c V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.2.0 \u003c V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.3.0), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions \u003e= V3.1.9 \u003c V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions \u003e= V3.1.8 \u003c V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application.\r\n\r\nFor compatibility reasons, fix versions still contain this issue, but only when the recommended, default configuration option `\u0027Use Encryption\u0027` is disabled."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-851884.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2023-08-08T10:15Z",
      "publishedDate": "2023-03-14T10:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.