GSD-2023-26788

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
Veritas Appliance v4.1.0.1 is affected by Host Header Injection attacks. HTTP host header can be manipulated and cause the application to behave in unexpected ways. Any changes made to the header would just cause the request to be sent to a completely different Domain/IP address.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-26788",
    "id": "GSD-2023-26788"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-26788"
      ],
      "details": "Veritas Appliance v4.1.0.1 is affected by Host Header Injection attacks. HTTP host header can be manipulated and cause the application to behave in unexpected ways. Any changes made to the header would just cause the request to be sent to a completely different Domain/IP address.",
      "id": "GSD-2023-26788",
      "modified": "2023-12-13T01:20:54.179281Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2023-26788",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Veritas Appliance v4.1.0.1 is affected by Host Header Injection attacks. HTTP host header can be manipulated and cause the application to behave in unexpected ways. Any changes made to the header would just cause the request to be sent to a completely different Domain/IP address."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://github.com/IthacaLabs/Veritas-Technologies",
            "refsource": "MISC",
            "url": "https://github.com/IthacaLabs/Veritas-Technologies"
          },
          {
            "name": "https://github.com/IthacaLabs/Veritas-Technologies/blob/main/Veritas%20Appliance%20v4.1.0.1/HHI/HHI_CVE-2023-26788.txt",
            "refsource": "MISC",
            "url": "https://github.com/IthacaLabs/Veritas-Technologies/blob/main/Veritas%20Appliance%20v4.1.0.1/HHI/HHI_CVE-2023-26788.txt"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:veritas:netbackup_appliance_firmware:4.1.0.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2023-26788"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Veritas Appliance v4.1.0.1 is affected by Host Header Injection attacks. HTTP host header can be manipulated and cause the application to behave in unexpected ways. Any changes made to the header would just cause the request to be sent to a completely different Domain/IP address."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/IthacaLabs/Veritas-Technologies",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://github.com/IthacaLabs/Veritas-Technologies"
            },
            {
              "name": "https://github.com/IthacaLabs/Veritas-Technologies/blob/main/Veritas%20Appliance%20v4.1.0.1/HHI/HHI_CVE-2023-26788.txt",
              "refsource": "MISC",
              "tags": [
                "Exploit",
                "Vendor Advisory"
              ],
              "url": "https://github.com/IthacaLabs/Veritas-Technologies/blob/main/Veritas%20Appliance%20v4.1.0.1/HHI/HHI_CVE-2023-26788.txt"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 2.7
        }
      },
      "lastModifiedDate": "2023-04-14T03:53Z",
      "publishedDate": "2023-04-10T13:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…