gsd-2023-29030
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-29030", "id": "GSD-2023-29030" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-29030" ], "details": "\nA cross site scripting vulnerability was discovered in Rockwell Automation\u0027s ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.\n\n", "id": "GSD-2023-29030", "modified": "2023-12-13T01:20:57.308891Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "PSIRT@rockwellautomation.com", "ID": "CVE-2023-29030", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ArmorStart ST", "version": { "version_data": [ { "version_affected": "=", "version_value": "All " } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\nA cross site scripting vulnerability was discovered in Rockwell Automation\u0027s ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-79", "lang": "eng", "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139438", "refsource": "MISC", "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139438" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Customers should disable the webserver during normal use. The webserver is disabled by default and should only be enabled to modify configurations. After modifying configurations, the web server should be disabled." } ], "value": "Customers should disable the webserver during normal use. The webserver is disabled by default and should only be enabled to modify configurations. After modifying configurations, the web server should be disabled." } ], "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:armorstart_st_284ee_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FB61010-9BC0-4A6D-BE43-350415D18374", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:armorstart_st_284ee:-:*:*:*:*:*:*:*", "matchCriteriaId": "07E85834-78DF-41E2-B86C-899DBE201D67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:rockwellautomation:armorstart_st_281e_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "8E001AA0-C1D7-4ADA-ADD9-4472276FA933", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:rockwellautomation:armorstart_st_281e:-:*:*:*:*:*:*:*", "matchCriteriaId": "462A5C89-68EB-471E-B23C-A2FA63EA74F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "\nA cross site scripting vulnerability was discovered in Rockwell Automation\u0027s ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation of this vulnerability.\n\n" } ], "id": "CVE-2023-29030", "lastModified": "2023-12-20T02:50:13.797", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.7, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.0, "impactScore": 5.9, "source": "PSIRT@rockwellautomation.com", "type": "Secondary" } ] }, "published": "2023-05-11T18:15:13.770", "references": [ { "source": "PSIRT@rockwellautomation.com", "tags": [ "Vendor Advisory" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139438" } ], "sourceIdentifier": "PSIRT@rockwellautomation.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "PSIRT@rockwellautomation.com", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.