gsd-2023-29158
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-29158",
    "id": "GSD-2023-29158"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-29158"
      ],
      "details": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n",
      "id": "GSD-2023-29158",
      "modified": "2023-12-13T01:20:57.345495Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2023-29158",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "PowerSYSTEM Center",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "0",
                          "version_value": "2020 U10"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "SUBNET Solutions Inc."
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "SUBNET Solutions reported these vulnerabilities to CISA."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-294",
                "lang": "eng",
                "value": "CWE-294 Authentication Bypass by Capture-replay"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
          }
        ]
      },
      "solution": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "work_around": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSUBNET Solutions recommends users to follow the following workarounds:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUsers should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\u003c/li\u003e\u003cli\u003eUsers should verify network security rules to ensure that outbound connections to the internet are not possible.\u003c/li\u003e\u003cli\u003eIf the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\u003c/li\u003e\u003cli\u003eMonitor user activity and ensure application control rules only allow preauthorized executables to run.\u003c/li\u003e\u003cli\u003eDeny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nSUBNET Solutions recommends users to follow the following workarounds:\n\n  *  Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\n  *  Users should verify network security rules to ensure that outbound connections to the internet are not possible.\n  *  If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\n  *  Monitor user activity and ensure application control rules only allow preauthorized executables to run.\n  *  Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\n\n\n\n\n\n\n"
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:2020:u10:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:2020:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "2020",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2023-29158"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-294"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.2
        }
      },
      "lastModifiedDate": "2023-06-29T20:14Z",
      "publishedDate": "2023-06-19T21:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.