Details
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-29158", "id": "GSD-2023-29158" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-29158" ], "details": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n", "id": "GSD-2023-29158", "modified": "2023-12-13T01:20:57.345495Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2023-29158", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PowerSYSTEM Center", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "0", "version_value": "2020 U10" } ] } } ] }, "vendor_name": "SUBNET Solutions Inc." } ] } }, "credits": [ { "lang": "en", "value": "SUBNET Solutions reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-294", "lang": "eng", "value": "CWE-294 Authentication Bypass by Capture-replay" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e" } ], "value": "\nSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\n\n\n\n\n" } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eSUBNET Solutions recommends users to follow the following workarounds:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUsers should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\u003c/li\u003e\u003cli\u003eUsers should verify network security rules to ensure that outbound connections to the internet are not possible.\u003c/li\u003e\u003cli\u003eIf the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\u003c/li\u003e\u003cli\u003eMonitor user activity and ensure application control rules only allow preauthorized executables to run.\u003c/li\u003e\u003cli\u003eDeny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\n\n\u003cbr\u003e" } ], "value": "\nSUBNET Solutions recommends users to follow the following workarounds:\n\n * Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\n * Users should verify network security rules to ensure that outbound connections to the internet are not possible.\n * If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\n * Monitor user activity and ensure application control rules only allow preauthorized executables to run.\n * Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\n\n\n\n\n\n\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:2020:u10:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:2020:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2020", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2023-29158" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-294" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2 } }, "lastModifiedDate": "2023-06-29T20:14Z", "publishedDate": "2023-06-19T21:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.