GSD-2023-29158
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-29158",
"id": "GSD-2023-29158"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-29158"
],
"details": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n",
"id": "GSD-2023-29158",
"modified": "2023-12-13T01:20:57.345495Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2023-29158",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerSYSTEM Center",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "2020 U10"
}
]
}
}
]
},
"vendor_name": "SUBNET Solutions Inc."
}
]
}
},
"credits": [
{
"lang": "en",
"value": "SUBNET Solutions reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-294",
"lang": "eng",
"value": "CWE-294 Authentication Bypass by Capture-replay"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
}
]
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "\nSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\n\n\n\n\n"
}
],
"source": {
"discovery": "INTERNAL"
},
"work_around": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eSUBNET Solutions recommends users to follow the following workarounds:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUsers should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\u003c/li\u003e\u003cli\u003eUsers should verify network security rules to ensure that outbound connections to the internet are not possible.\u003c/li\u003e\u003cli\u003eIf the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\u003c/li\u003e\u003cli\u003eMonitor user activity and ensure application control rules only allow preauthorized executables to run.\u003c/li\u003e\u003cli\u003eDeny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nSUBNET Solutions recommends users to follow the following workarounds:\n\n * Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\n * Users should verify network security rules to ensure that outbound connections to the internet are not possible.\n * If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\n * Monitor user activity and ensure application control rules only allow preauthorized executables to run.\n * Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\n\n\n\n\n\n\n"
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:2020:u10:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:2020:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2020",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2023-29158"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-294"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
},
"lastModifiedDate": "2023-06-29T20:14Z",
"publishedDate": "2023-06-19T21:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…