Summary
SUBNET PowerSYSTEM Center Authentication Bypass by Capture-replay
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01Third Party Advisory, US Government Resource
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:15.368Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerSYSTEM Center",
          "vendor": "SUBNET Solutions Inc.",
          "versions": [
            {
              "lessThanOrEqual": "2020 U10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "SUBNET Solutions reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2023-06-15T20:07:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\u003c/span\u003e\n\n\u003c/p\u003e\u003cbr\u003e\n\n"
            }
          ],
          "value": "\n\n\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\n\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-294",
              "description": "CWE-294 Authentication Bypass by Capture-replay",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-19T20:11:05.873Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\u003c/p\u003e\u003cp\u003e\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nSUBNET Solutions has fixed these issues by enabling a file integrity check on uploaded images and anti-forgery tokens to prevent replay attacks. The fix was introduced in PowerSYSTEM Center update 12 as well as Update 8+Hotfix (both identified by release number 5.12.2305.10101, which can be located in Settings / Overview / Version).\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "SUBNET PowerSYSTEM Center Authentication Bypass by Capture-replay",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eSUBNET Solutions recommends users to follow the following workarounds:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUsers should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\u003c/li\u003e\u003cli\u003eUsers should verify network security rules to ensure that outbound connections to the internet are not possible.\u003c/li\u003e\u003cli\u003eIf the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\u003c/li\u003e\u003cli\u003eMonitor user activity and ensure application control rules only allow preauthorized executables to run.\u003c/li\u003e\u003cli\u003eDeny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nSUBNET Solutions recommends users to follow the following workarounds:\n\n  *  Users should verify that SVG files do not contain HTML elements or scripts and validate that JPG and PNG files are not SVG files.\n  *  Users should verify network security rules to ensure that outbound connections to the internet are not possible.\n  *  If the above cannot be performed or notifications are not required, disable email notifications for reports from PowerSYSTEM Center.\n  *  Monitor user activity and ensure application control rules only allow preauthorized executables to run.\n  *  Deny users to run other executables on client access servers (PowerSYSTEM Center front end access point).\n\n\n\n\n\n\n"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-29158",
    "datePublished": "2023-06-19T20:11:05.873Z",
    "dateReserved": "2023-05-25T16:04:56.578Z",
    "dateUpdated": "2024-08-02T14:00:15.368Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-29158\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-06-19T21:15:42.033\",\"lastModified\":\"2023-06-29T20:14:11.297\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\n\\n\\nSUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity.\\n\\n\\n\\n\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:subnet:powersystem_center:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2020\",\"matchCriteriaId\":\"D5778648-23B8-4022-904D-E8B631E5FFD7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:subnet:powersystem_center:2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EDB93B1-836B-47CD-8D4A-4DFF281DEC91\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:subnet:powersystem_center:2020:u10:*:*:*:*:*:*\",\"matchCriteriaId\":\"F5575977-3DFF-44B4-A0E1-4C3C9E92CD3E\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.