GSD-2023-29183

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
An improper neutralization of input during web page generation ('Cross-site Scripting') vulnerability [CWE-79] in FortiProxy 7.2.0 through 7.2.4, 7.0.0 through 7.0.10 and FortiOS 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.14 GUI may allow an authenticated attacker to trigger malicious JavaScript code execution via crafted guest management setting.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-29183",
    "id": "GSD-2023-29183"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-29183"
      ],
      "details": "An improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027) vulnerability [CWE-79] in FortiProxy 7.2.0 through 7.2.4, 7.0.0 through 7.0.10 and FortiOS 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.14 GUI may allow an authenticated attacker to trigger malicious JavaScript code execution via crafted guest management setting.",
      "id": "GSD-2023-29183",
      "modified": "2023-12-13T01:20:57.051483Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@fortinet.com",
        "ID": "CVE-2023-29183",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "FortiProxy",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "7.2.0",
                          "version_value": "7.2.4"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "7.0.0",
                          "version_value": "7.0.10"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "FortiOS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c=",
                          "version_name": "7.2.0",
                          "version_value": "7.2.4"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "7.0.0",
                          "version_value": "7.0.11"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "6.4.0",
                          "version_value": "6.4.12"
                        },
                        {
                          "version_affected": "\u003c=",
                          "version_name": "6.2.0",
                          "version_value": "6.2.14"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Fortinet"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "An improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027) vulnerability [CWE-79] in FortiProxy 7.2.0 through 7.2.4, 7.0.0 through 7.0.10 and FortiOS 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.14 GUI may allow an authenticated attacker to trigger malicious JavaScript code execution via crafted guest management setting."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-79",
                "lang": "eng",
                "value": "Execute unauthorized code or commands"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-23-106",
            "refsource": "MISC",
            "url": "https://fortiguard.com/psirt/FG-IR-23-106"
          }
        ]
      },
      "solution": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiProxy version 7.2.5 or above Please upgrade to FortiProxy version 7.0.11 or above Please upgrade to FortiOS version 7.4.0 or above Please upgrade to FortiOS version 7.2.5 or above Please upgrade to FortiOS version 7.0.12 or above Please upgrade to FortiOS version 6.4.13 or above Please upgrade to FortiOS version 6.2.15 or above "
        }
      ]
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.2.5",
                "versionStartIncluding": "7.2.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "6.4.13",
                "versionStartIncluding": "6.4.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.0.12",
                "versionStartIncluding": "7.0.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "6.2.15",
                "versionStartIncluding": "6.2.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.2.5",
                "versionStartIncluding": "7.2.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.0.11",
                "versionStartIncluding": "7.0.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@fortinet.com",
          "ID": "CVE-2023-29183"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "An improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027) vulnerability [CWE-79] in FortiProxy 7.2.0 through 7.2.4, 7.0.0 through 7.0.10 and FortiOS 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.14 GUI may allow an authenticated attacker to trigger malicious JavaScript code execution via crafted guest management setting."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://fortiguard.com/psirt/FG-IR-23-106",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://fortiguard.com/psirt/FG-IR-23-106"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 2.3,
          "impactScore": 2.7
        }
      },
      "lastModifiedDate": "2023-09-15T13:23Z",
      "publishedDate": "2023-09-13T13:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…