In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-37551", "id": "GSD-2023-37551" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-37551" ], "details": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.", "id": "GSD-2023-37551", "modified": "2023-12-13T01:20:24.523315Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2023-37551", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V4.10.0.0" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } }, { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } }, { "product_name": "CODESYS Safety SIL2 Runtime Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.5.19.20" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "credits": [ { "lang": "en", "value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-552", "lang": "eng", "value": "CWE-552 Files or Directories Accessible to External Parties" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en/advisories/VDE-2023-019/", "refsource": "MISC", "url": "https://cert.vde.com/en/advisories/VDE-2023-019/" } ] }, "source": { "advisory": "VDE-2023-019", "defect": [ "CERT@VDE#64558" ], "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.10.0.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.19.20", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2023-37551" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-552" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en/advisories/VDE-2023-019/", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-019/" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } }, "lastModifiedDate": "2023-08-08T15:42Z", "publishedDate": "2023-08-03T12:15Z" } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.