GSD-2023-37551
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-37551",
"id": "GSD-2023-37551"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-37551"
],
"details": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.",
"id": "GSD-2023-37551",
"modified": "2023-12-13T01:20:24.523315Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"ID": "CVE-2023-37551",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CODESYS Control for BeagleBone SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for emPC-A/iMX6 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for IOT2000 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for Linux SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for PFC100 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for PFC200 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for PLCnext SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for Raspberry Pi SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V4.10.0.0"
}
]
}
},
{
"product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
},
{
"product_name": "CODESYS Control RTE (SL)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
},
{
"product_name": "CODESYS Control Runtime System Toolkit",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
},
{
"product_name": "CODESYS Control Win (SL)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
},
{
"product_name": "CODESYS Development System V3",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
},
{
"product_name": "CODESYS HMI (SL)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
},
{
"product_name": "CODESYS Safety SIL2 Runtime Toolkit",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "0",
"version_value": "V3.5.19.20"
}
]
}
}
]
},
"vendor_name": "CODESYS"
}
]
}
},
"credits": [
{
"lang": "en",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-552",
"lang": "eng",
"value": "CWE-552 Files or Directories Accessible to External Parties"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2023-019/",
"refsource": "MISC",
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
]
},
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"ID": "CVE-2023-37551"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2023-019/",
"refsource": "MISC",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-08-08T15:42Z",
"publishedDate": "2023-08-03T12:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…