GSD-2023-4518
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
A vulnerability exists in the input validation of the GOOSE
messages where out of range values received and processed
by the IED caused a reboot of the device. In order for an
attacker to exploit the vulnerability, goose receiving blocks need
to be configured.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-4518",
"id": "GSD-2023-4518"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-4518"
],
"details": "A vulnerability exists in the input validation of the GOOSE \nmessages where out of range values received and processed \nby the IED caused a reboot of the device. In order for an \nattacker to exploit the vulnerability, goose receiving blocks need \nto be configured.\u00a0",
"id": "GSD-2023-4518",
"modified": "2023-12-13T01:20:26.625657Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@hitachienergy.com",
"ID": "CVE-2023-4518",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Relion670",
"version": {
"version_data": [
{
"version_value": "not down converted",
"x_cve_json_5_version_data": {
"defaultStatus": "affected",
"versions": [
{
"status": "affected",
"version": " Relion 670 series version 2.2.0 all revisions"
},
{
"status": "affected",
"version": "Relion 670/650/SAM600-IO series version 2.2.1 all revisions"
},
{
"status": "affected",
"version": "elion 670 series version 2.2.2 all revisions"
},
{
"status": "affected",
"version": "Relion 670 series version 2.2.3 all revisions"
},
{
"status": "affected",
"version": "Relion 670/650 series version 2.2.4 all revisions"
},
{
"status": "affected",
"version": "Relion 670/650/SAM600-IO series version 2.2.5 all revisions"
}
]
}
}
]
}
}
]
},
"vendor_name": "Hitachi Energy"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in the input validation of the GOOSE \nmessages where out of range values received and processed \nby the IED caused a reboot of the device. In order for an \nattacker to exploit the vulnerability, goose receiving blocks need \nto be configured.\u00a0"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-20",
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000170\u0026languageCode=en\u0026Preview=true",
"refsource": "MISC",
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000170\u0026languageCode=en\u0026Preview=true"
}
]
},
"source": {
"advisory": " 8DBD000170",
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.2.6",
"versionStartIncluding": "2.2.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.3.7",
"versionStartIncluding": "2.2.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.4.4",
"versionStartIncluding": "2.2.4",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.5.6",
"versionStartIncluding": "2.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.4.4",
"versionStartIncluding": "2.2.4",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.5.6",
"versionStartIncluding": "2.2.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.5.6",
"versionStartIncluding": "2.2.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@hitachi-powergrids.com",
"ID": "CVE-2023-4518"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability exists in the input validation of the GOOSE \nmessages where out of range values received and processed \nby the IED caused a reboot of the device. In order for an \nattacker to exploit the vulnerability, goose receiving blocks need \nto be configured.\u00a0"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-1284"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000170\u0026languageCode=en\u0026Preview=true",
"refsource": "",
"tags": [
"Vendor Advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000170\u0026languageCode=en\u0026Preview=true"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-12-06T18:55Z",
"publishedDate": "2023-12-01T15:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…