GSD-2023-45321

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-45321",
    "id": "GSD-2023-45321"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-45321"
      ],
      "details": "The Android Client application, when enrolled with the define  method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.",
      "id": "GSD-2023-45321",
      "modified": "2023-12-13T01:20:38.430230Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@bosch.com",
        "ID": "CVE-2023-45321",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2107)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2110)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2115)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Bosch Rexroth AG"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The Android Client application, when enrolled with the define  method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-319",
                "lang": "eng",
                "value": "CWE-319 Cleartext Transmission of Sensitive Information"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
            "refsource": "MISC",
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "ID": "CVE-2023-45321"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The Android Client application, when enrolled with the define  method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-319"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Vendor Advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-11-06T14:44Z",
      "publishedDate": "2023-10-25T18:17Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…