GSD-2023-46102

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
The Android Client application, when enrolled to the AppHub server, connects to an MQTT broker to exchange messages and receive commands to execute on the HMI device. The protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application. This issue allows an attacker able to control a malicious MQTT broker on the same subnet network of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-46102",
    "id": "GSD-2023-46102"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-46102"
      ],
      "details": "The Android Client application, when enrolled to the AppHub server, connects to an MQTT\r\nbroker to exchange messages and receive commands to execute on the HMI device.\r\nThe protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.\r\n\r\n\r\nThis issue allows an attacker able to control a malicious MQTT broker on the same subnet\r\nnetwork of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself.",
      "id": "GSD-2023-46102",
      "modified": "2023-12-13T01:20:52.905135Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@bosch.com",
        "ID": "CVE-2023-46102",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2107)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2110)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "ctrlX HMI Web Panel - WR21 (WR2115)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Bosch Rexroth AG"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The Android Client application, when enrolled to the AppHub server, connects to an MQTT\r\nbroker to exchange messages and receive commands to execute on the HMI device.\r\nThe protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.\r\n\r\n\r\nThis issue allows an attacker able to control a malicious MQTT broker on the same subnet\r\nnetwork of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-798",
                "lang": "eng",
                "value": "CWE-798 Use of Hard-coded Credentials"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
            "refsource": "MISC",
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "ID": "CVE-2023-46102"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The Android Client application, when enrolled to the AppHub server, connects to an MQTT\r\nbroker to exchange messages and receive commands to execute on the HMI device.\r\nThe protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.\r\n\r\n\r\nThis issue allows an attacker able to control a malicious MQTT broker on the same subnet\r\nnetwork of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-798"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Vendor Advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-11-06T14:33Z",
      "publishedDate": "2023-10-25T18:17Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…