GSD-2023-46381

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
LOYTEC LINX-212 firmware 6.2.4 and LVIS-3ME12-A1 firmware 6.2.2 and LIOB-586 firmware 6.2.3 devices lack authentication for the preinstalled version of LWEB-802 via an lweb802_pre/ URI. An unauthenticated attacker can edit any project (or create a new project) and control its GUI.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-46381",
    "id": "GSD-2023-46381"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-46381"
      ],
      "details": "LOYTEC LINX-212 firmware 6.2.4 and LVIS-3ME12-A1 firmware 6.2.2 and LIOB-586 firmware 6.2.3 devices lack authentication for the preinstalled version of LWEB-802 via an lweb802_pre/ URI. An unauthenticated attacker can edit any project (or create a new project) and control its GUI.",
      "id": "GSD-2023-46381",
      "modified": "2023-12-13T01:20:53.310268Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2023-46381",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "LOYTEC LINX-212 firmware 6.2.4 and LVIS-3ME12-A1 firmware 6.2.2 and LIOB-586 firmware 6.2.3 devices lack authentication for the preinstalled version of LWEB-802 via an lweb802_pre/ URI. An unauthenticated attacker can edit any project (or create a new project) and control its GUI."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://seclists.org/fulldisclosure/2023/Nov/0",
            "refsource": "MISC",
            "url": "https://seclists.org/fulldisclosure/2023/Nov/0"
          },
          {
            "name": "http://packetstormsecurity.com/files/175646/LOYTEC-Electronics-Insecure-Transit-Insecure-Permissions-Unauthenticated-Access.html",
            "refsource": "MISC",
            "url": "http://packetstormsecurity.com/files/175646/LOYTEC-Electronics-Insecure-Transit-Insecure-Permissions-Unauthenticated-Access.html"
          },
          {
            "name": "https://www.txone.com/blog/ten-unpatched-vulnerabilities-in-building-automation-products-identified-by-txone-networks/",
            "refsource": "MISC",
            "url": "https://www.txone.com/blog/ten-unpatched-vulnerabilities-in-building-automation-products-identified-by-txone-networks/"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:loytec:linx-212_firmware:6.2.4:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0C622E98-9108-440E-B554-EBE91708B534",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:loytec:linx-212:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "35956253-8D61-434C-9C03-96E6C69FB9C1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:loytec:lvis-3me12-a1_firmware:6.2.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "338AF9A1-BD5E-4955-B9F2-BF38F1D33660",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:loytec:lvis-3me12-a1:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D31C7C60-0476-43F9-9471-1976F569B9DE",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:loytec:liob-586_firmware:6.2.3:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1B2AE346-27B5-45B0-9DF9-AE4DF99377D8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:loytec:liob-586:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "798F75E0-8B29-4F1B-BBB8-82B97CBC7138",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "LOYTEC LINX-212 firmware 6.2.4 and LVIS-3ME12-A1 firmware 6.2.2 and LIOB-586 firmware 6.2.3 devices lack authentication for the preinstalled version of LWEB-802 via an lweb802_pre/ URI. An unauthenticated attacker can edit any project (or create a new project) and control its GUI."
          },
          {
            "lang": "es",
            "value": "Los dispositivos LOYTEC LINX-212 firmware 6.2.4 y LVIS-3ME12-A1 firmware 6.2.2 y LIOB-586 firmware 6.2.3 carecen de autenticaci\u00f3n para la versi\u00f3n preinstalada de LWEB-802 a trav\u00e9s de un URI lweb802_pre/. Un atacante no autenticado puede editar cualquier proyecto (o crear un proyecto nuevo) y controlar su GUI."
          }
        ],
        "id": "CVE-2023-46381",
        "lastModified": "2023-12-14T08:15:41.450",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 4.2,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2023-11-04T23:15:07.957",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "http://packetstormsecurity.com/files/175646/LOYTEC-Electronics-Insecure-Transit-Insecure-Permissions-Unauthenticated-Access.html"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Mailing List",
              "Third Party Advisory"
            ],
            "url": "https://seclists.org/fulldisclosure/2023/Nov/0"
          },
          {
            "source": "cve@mitre.org",
            "url": "https://www.txone.com/blog/ten-unpatched-vulnerabilities-in-building-automation-products-identified-by-txone-networks/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-306"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…